beautypg.com

Patton electronic 1050patton User Manual

Page 8

background image

APPENDIX B

PATTON MODEL 1050 CABLE RECOMMENDATIONS

All Patton Electronics Company Short Range Modems are tested to

the distances published in our Catalogs and Specification Sheets on
twisted-pair cable with the following characteristics:

Wire Gauge

Capacitance

Resistance

19 AWG(.9mm) 83nF/mi or 15.72 pF/ft.

.0163

/ft.

22 AWG(.6mm) 83nF/mi or 15.72 pF/ft.

.0326

/ft.

24 AWG(.5mm) 83nF/mi or 15.72 pF/ft.

.05165

/ft.

26 AWG(.4mm) 83nF/mi or 15.72 pF/ft.

.08235

/ft.

We fully expect that the Short Range Modems will operate on lines

with specifications different from those tested, but to reduce the
potential difficulties in the field, one should ensure that the cable being
used has similar or better characteristics (lower capacitance or lower
resistance).

Wire with capacitance of 20pF/ft. or less is suitable for all our Short

Range Modems however, distances may vary from those published in
our catalog. Resistance will also affect distance but not functionality.
Wire should be 26 AWG (.4mm) (or larger (smaller AWG#).

Patton products are designed to withstand normal environmental

noise and conditions however, other environmental factors too
numerous to discuss in this format may affect proper operation of the
SRM’s.

Selection of the proper SRM for an application is critical to

maintaining Customer Satisfaction and should be taken seriously.
Certain models are better suited for particular applications and
environments than others.

APPENDIX C

PATTON MODEL 1050 INTERFACE PIN ASSIGNMENT

RS-232 FEMALE, D-SUB 25 CONNECTOR

(DCE ORIENTATION)

1- (FG) Frame Ground
2- (TD) Transmit Data

To 1050

3- (RD) Receive Data

From 1050

4- (RTS) Request to Send

To 1050

5- (CTS) Clear to Send

From 1050

6- (DSR) Data Set Ready

From 1050

7- (SG) Signal Ground
8- (DCD) Data Carrier Detect

From 1050

DIRECTION

STANDARD RS-232C/V.24 “DCE” SETTING

DIRECTION

1- (FG) Frame Ground
2- (TD) Transmit Data

From 1050

3- (RD) Receive Data

To 1050

4- (RTS) Request to Send

From 1050

7- (SG) Signal Ground
8- (DCD) Data Carrier Detect

To 1050

From 1050

Data Term. Ready (DTR) - 20

DIRECTION

STANDARD RS-232C/V.24 “DTE” SETTING

DIRECTION

13

14