beautypg.com

Cup insulator and o-ring maintenance – Python LIQUID COOLED MILLERMATIC COMPATIBLE 248-8XX User Manual

Page 27

background image

Liquid Cooled Millermatic Compatible™ Python

®

Owner's Manual - page 16

CUP INSULATOR AND O-RING MAINTENANCE

CAUTION: Power-off the coolant pump before disassembling liquid-cooled barrels.

1. Unscrew Retaining Nut and slide back on barrel.
2. Using a firm pull and twist action, the Liquid-Cooled Gas Cup can be removed from the Cup

Insulator.

3. Inspect the Cup Insulator and o-rings (included with Insulator) for wear and proper lubrication.

It is considered good practice to replace all o-rings at the same time.

4. To remove the Cup Insulator, it must be UNSCREWED and pulled from the barrel. Use a rag

or towel (due to o-ring lubrication) and wrap it around the Cup Insulator.
UNSCREW and pull when completly unthreaded from barrel. Be sure the Insulator is fully

unscrewed from the threads. Pulling the Insulator over barrel threads will damage the

threads on the Insulator.
Inspect o-rings on barrel for wear and lubrication. It is considered good practice to replace all

o-rings at the same time.

5. To install the Cup Insulator, it must be pushed all the way onto the barrel then screwed onto

the threads. If necessary, place small amount of o-ring lubricant on the inside diameter of the

Cup Insulator, this will help it slide onto the barrel.
Push the Insulator onto the barrel until it bottoms out, screw onto barrel threads.
The Insulator MUST be all the way onto the barrel to assure proper coolant passage and from

blocking the gas outlet orifices.

6. Push Liquid-Cooled Gas Cup onto Cup Insulator. Slide Retaining Nut forward and tighten.

Incorrect Installation

Correct Installation

Insulator

Barrel

Gas Outlet Orifices