beautypg.com

Patton electronic 2720/I Series User Manual

Page 11

background image

Switch S2-6 and S2-7: Clock Mode

Set Switch S2-6 and S2-7 to determine the 2720’s transmitter tim-

ing.

S2-6

S2-7

Clock Mode

Off

Off

Network Clock

. Transmitter timing is

derived from the received line signal.

On

Off

Internal Clock

. Transmitter clock is

derived from an internal oscillator.

NOTE 1: When using the Model 2720 as a high-speed short
range modem, one unit of the link must be configured in Internal
Clock mode, and the opposite end unit must be configured for
Network Clock mode.

If the ERR LED on the front of the unit is flashing (or on) it could
be an indication of a clocking problem. Double check your clock
mode settings and Tx Clock Invert S1-3 settings.

Switch S2-8 Reserved

Substitution (B8ZS): This mode assures proper bit density
in the data stream. In this mode any data pattern can be
transmitted without causing ones density errors. This mode
allows for 64 kbps clear channel timeslots.

Switch S2-5: DS0 Channel Rate

Use Switch S2-5 to set the DS0 rate.

SW2-5

Setting

Off

56 kbps

On

64 kbps

9

10

S2 SUMMARY TABLE

Position

Function

Factory Default

Selected Option

S2-1

Data Rate

On

S2-2

Data Rate

On

S2-3

Data Rate

On

S2-4

Framing & Coding

Off

S2-5

DS0 Rate

On

S2-6

Clock Mode

Off

S2-7

Clock Mode

Off

S2-8

Reserved

Off

1.536 Mbps

(DTE Rate)

ESF/B8ZS

64 kbps

Network

Reserved

Network