beautypg.com

Patton electronic 1094 User Manual

Page 5

background image

7

8

Switch S1-8: V.54 Enable / Disable

The setting for switch S1-8 determines whether the Model 1094

will respond when it receives the V.54 sequence. If you suspect the
Model 1094 may be getting tricked into the loopback test by false
detection of user data, you can try setting this to “Disable.”

S1-8

Setting

On

Disabled

Off

Enabled

3.1.2 Switch Set S2

The settings for DIP switches S2-1 through S2-4 determine the

synchronous data rate of the Model 1094. All possible settings (includ-
ing the default) are shown below:

S2-1

S2-2

S2-3

S2-4

Setting

Off

On

On

On

384 kbps

On

Off

Off

Off

768 kbps (default)

4.0 INSTALLATION

Once the Model 1094 is properly configured, it is ready to connect

to the twisted pair interface, to the serial port, and to the power source.
This section tells you how to make these connections.

4.1 CONNECTION TO THE TWISTED PAIR INTERFACE

The Model 1094 supports communication between two terminal

devices at distances to 4.9 miles (7.9 km) and data rates to 768 kbps.
There are two essential requirements for installing the Model 1094:

1.

These units work in pairs. Therefore, you must have one
Model 1094 (or a compatible model) at each end of a two
twisted pair interface.

2.

To function properly, the Model 1094 needs two twisted pairs
of metallic wire. These twisted pairs must be
unconditioned, dry, metallic wire, between 19 and 26 AWG
(.4 mm and .9 mm, inversely) (the higher AWG gauges may
limit distance somewhat). Standard dial-equalization
equipment, or standard, flat modular telephone type cable, are
not acceptable.

4.1.1 TWISTED PAIR CONNECTION USING RJ-45

The Model 1094 uses a modular RJ-45 jack for twisted pair line

connection. The signal/pin relationships are shown below:

RJ-45

SIGNAL

1 ..........................XMT+
2 ..........................XMT-
3 ..........................N/C
4 ..........................GND*
5 ..........................GND*
6 ..........................N/C
7 ..........................RCV+
8 ..........................RCV-

*Connection to ground is optional

1
2
3
4
5
6
7
8