3.2 RACK CARD INSTALLATION

The Model 1068 rack card version comprises a front card and a rear
card.Do the following to install the cards into the rack chassis:

1. Slide the rear card into the back of the chassis along the metal rails.

2. Secure the rear card using the supplied metal screws.

3. Slide the front card into the chassis until you feel resistance as the

front card engages the rear card. When that happens,

gently

push

the front card forward until it is fully seated in the card-edge recepta-
cle of the rear card (it should

click

into place).

4. Secure the front card using the captive fasteners.

Note

The Model 1001R14 chassis supports “hot swapping” of cards,

so it is not necessary to power down the rack when you install or
remove a Model 1068 rack card.

Figure 3.

Model 1068 rack cards

5. Connect the line interface between the units (refer to section 3.3,

“Connecting the Twisted-Pair Line Interface” on page 11)

Note

See Figure 3 for the rack card’s panel arrangements.