Connection examples, Aes/ebu connections, Ad8hr daisy chain connection – Pacific Digital AD8HR User Manual
Page 10: Aes/ebu connections ad8hr daisy chain connection
10
Connection Examples
AES/EBU Connections
Use a D-sub 25-pin AES/EBU cable to connect a
digital audio device that supports the AES/EBU
format. To connect a Yamaha PM5D or DM2000 to
the AD8HR, first you must install an optional I/O card
(MY8-AE, MY8-AE96S, MY8-AE96, or MY16-AE) in
the PM5D or DM2000.
AD8HR Daisy Chain Connection
You can connect multiple AD8HRs to a Yamaha
PM5D or DM2000. Connect [HA REMOTE]
connector 1 of the first AD8HR to the COM connector
of the DM2000, and connect [HA REMOTE]
connector 2 to [HA REMOTE] connector 1 of the
second AD8HR. Set the [PC RS422] switches on both
AD8HRs to RS422. Specify the DM2000 as the
wordclock master, and set the wordclock source on the
AD8HR to DIGITAL OUT A.
Connection Examples
DIGITAL OUT A/B
AD8HR
+48V
HPF
dB
96kHz
88.2kHz
48kHz
44.1kHz
+48V
OFF ON
MASTER
WORD CLOCK
Digital audio devices
(PM5D, DM2000, etc.)
Analog in x 8
Optional I/O card
AES/EBU cable
COM
SLOT 1
SLOT 2
HA REMOTE 2
HA REMOTE 2
DIGITAL
OUT A
HA REMOTE 1
HA REMOTE 1
AD8HR #1
+48V
HPF
dB
96kHz
88.2kHz
48kHz
44.1kHz
+48V
OFF ON
MASTER
WORD CLOCK
DIGITAL
OUT A
AD8HR #2
+48V
HPF
dB
96kHz
88.2kHz
48kHz
44.1kHz
+48V
OFF ON
MASTER
WORD CLOCK
Digital audio devices
(PM5D, DM2000, etc.)
Analog in x 8
Analog in x 8