15- ENG

D24225

MAINTENANCE

NOTE: See "Operation" section for the location of controls.

To ensure efficient operation and longer life of the air compressor outfit, a
routine maintenance schedule should be prepared and followed. The following
routine maintenance schedule is geared to an outfit in a normal working
environment operating on a daily basis. If necessary, the schedule should be
modified to suit the conditions under which your compressor is used. The
modifications will depend upon the hours of operation and the working
environment. Compressor outfits in an extremely dirty and/or hostile
environment will require a greater frequency of all maintenance checks.

Unit cycles automatically when power is on. When
performing maintenance, you may be exposed to voltage

sources, compressed air, or moving parts. Personal injuries can occur.
Before performing any maintenance or repair, disconnect power source
from the compressor and bleed off all air pressure.

To Check Safety Valve

If the safety valve does not work properly, over-
pressurization may occur, causing air tank rupture or an

explosion.

1.

Before starting compressor, pull the ring on the safety valve to make sure
that the safety valve operates freely. If the valve is stuck or does not
operate smoothly, it must be replaced with the same type of valve.

Customer Responsibilities

Before
each
use

2

Every
8
hours

Every
40
hours

Every
100
hours

Yearly

Every
160
hours

1

1- more frequent in dusty or humid conditions

2- more frequent if humidity or operating conditions are extreme.

Check Safety Valve

Drain Tank
Check Oil

Change Oil

Air Filter

Unusual Noise and/or
Vibration

Drive Belt-Condition

Motor Pulley/Flywheel alignment

Air compressor pump intake
and exhaust valves

Inspect air lines and fittings
for leaks

2

Head Bolts - Check the torques of the head bolts after the first five hours of operation.

Every
500