beautypg.com

External 48 vdc power supply – Patton electronic 2156 User Manual

Page 12

background image

12

External 48 VDC power supply

• Input

Rated voltage: 36–60 VDC

Rated current: 0.25 A DC at nominal 48 VDC

3-pin locking connector, 3.5 mm pitch

Reverse polarity protection

Transient over-voltage protection, 100 VDC at 2 ms

• Output

Rated voltage: 5 VDC ± 5%, 5W

Rated current; 1 A DC

6-inch cable terminated with 2.5 mm barrel plug, center positive

Caution

An approved external power supply that incorporates a
disconnect device must be used and positioned within
easy reach of the operator’s position.

Caution

Connect the equipment to a 5 VDC source that is electri-
cally isolated from the AC source. The 5 VDC source is to
be reliably connected to earth.

Caution

An approved external power supply that incorporates a
disconnect device must be used and positioned within
easy reach of the operator’s position.

Caution

Connect the equipment to a 36–60 VDC source that is
electrically isolated from the AC source. The 36–60 VDC
source is to be reliably connected to earth.

This manual is related to the following products: