Software device features, Cab 16i, Typical network connections (figure 4) – Peavey COBRANET AUDIO BRIDGE CAB 16D User Manual
Page 12: Cab 16i software device features
CAB
™
16 Series User Manual
Page 12
http://aa.peavey.com copyright 2000 All Rights Reserved
CAB 16i Software Device Features
LINK LED This LED will turn ON when a valid connection has been established between the
CAB 16 and the network switch. This function is duplicated on the front panel of the CAB 16i.
ID The four digit number is the user-defined Hardware Base Address. The range is hex,
between 0000 and FFFF. The LED will turn ON when a valid number is entered. Each CAB
16 on the network must have a unique ID. If there is a duplicate, or the value is zero, this LED
will not light, and communications between the CAB and network is not valid.
BUNDLE User defined number that assigns eight audio channels to a CobraNet
™
network
“bundle”. The range is OFF to 32,767. For switched networks, the number must be 256 or
higher. This number must also be set in the CobraNet I/O device for which the CAB will
transport audio. The LED is ON when the CAB 16i is receiving the specified network bundle.
Each CAB 16i can receive two separate audio bundles.
GAIN Software control of the CAB 16i’s analog gain stage. Gesturable from the knob or the
digital window located just above each knob. The range is -95.5 dB to +30.5 dB.
FULL-SCALE SENSITIVITY BLOCK When clicked upon, this block opens an additional
window that includes buttons for adjusting the CAB 16i’s input sensitivity. There are two
windows, one for channels 1-8, and another for channels 9-16. A single-click in Control Mode,
or a double-click in Edit Mode will open this block.
FULL-SCALE SENSITIVITY DIALOG This window reveals the CAB 16i’s input channel
analog sensitivity settings. There are four settings for each input channel. The levels indicate
a maximum setting and allow the user to “shift” the available dynamic range for flexibility in
matching nominal incoming signal levels. When the GAIN control is at 0 dB, the input sensi-
tivity is determined solely by the Full Scale Sensitivity button.