background image

MACH® Series

Gas-Fired Boiler

Parts and Technical Support

Page 38

6.1.1a Terminal Block Assignments – Low Voltage Circuit (TB1)

Terminal Number

Label

Description

1 HEAT

REQUEST

2 HEAT

REQUEST

Boiler Enable, Contact Closure.

DO NOT ENERGIZE.

3 INTERLOCK

JUMPER

4 INTERLOCK

JUMPER

External Limit (auto reset), Contact Closure.

DO NOT ENERGIZE.

5

DHW TEMP. SENSOR

6

OUTDOOR TEMP SENSOR

Thermistor - factory option.

7

CIRC. PMP PWM SIGNAL

Pulse Width Modulation.

8

COMMON

Common to be used with 5, 6, 7, and 10 when used.

9

COMMON

Common to be used with 5, 6, 7, and 10 when used.

10

O-10 V ANAL. INPUT CONTROL Remote control of firing rate or setpoint.

11

+10 VOLT

Regulated 10V output.

12

COM 1

RS-485 port A.

13

COM 2

RS-485 port B.

14

OUTSIDE TEMP W/ FILTER

Thermistor - factory option.

15

OUTSIDE TEMP W/ FILTER

Thermistor - factory option.

16 SPARE

17 SPARE