beautypg.com

Gas requirements, Electrical requirements, Short form specification – Pitco Frialator SG14R User Manual

Page 2: Typical applications

background image

Pitco Frialator, Inc., P.O. Box 501, Concord, NH 03302-0501

1

509 Route 3A, Bow NH 03304, USA

(603) 225-6684

• Fax (603) 225-8472 •

www.pitco.com

L10-134 Rev 4 (02/07) Printed in the USA

Model FD Solstice Filter Drawer

Filter Drawer (FD) and System Solstice Models

We reserve the right to change specifications without notice and without incurring any obligation for equipment previously or subsequently sold.

5/8 [1.6]

9 [22.9]

REQUIRED TO REMOVE

MINIMUM AISLE SPACE

30 [76.2]

NOM.

12 [30.5]

34 [86.4]

NOM.

FILTER PAN

11/16 [1.7]

34 3/8 [87.3]

1 5/16 [3.3]

46 1/8 [117.2]

NOM.

10 ½

[26.7]

A

INTEGRAL

FLUE DEFLECTOR

OPTIONAL

BASKET LIFT

2. 6 FOOT (183 CM) POWER SUPPLY CORD

1. 6 FOOT (183 CM) POWER SUPPLY CORD

(NEMA 5-15 PLUG ON 115VAC UNITS ONLY)

SUPPLIED WITH UPGRADED CONTROLS

SUPPLIED WITH FILTER SYSTEM

REAR

TEE GAS

CONNECTION

4 3/8 [11.1]

21 29/32 [55.6]

2

5

1

4

L

3

8

R

7

0

6

9

2

5

1

4

L

3

8

R

7

0

6

9

INCHES [CENTIMETERS]

GAS REQUIREMENTS

Gas Rear Tee Manifold

Maximum Number of

Fryer Positions Per Manifold

Rear Tee Gas Connection Location

Gas Connection Size

SG14S, SG14RS,

SG14TS, SG18S,

SGBNB14, SGBNB18

4 fryer positions allowed;

include BNB unit in position count.

Default location is to the left. Connection

is field reversible to the right.

1-¼” NPT (1-¼” BSP CE AuGA) for 367 KBTU / 108 kW / 387 mJ

to 560 KBTU / 164 kW / 591 mJ.

1 “ NPT (1” BSP CE, AuGA) up to 366 kBTU / 107 kW / 386 mJ.
¾” NPT (¾” BSP CE, AuGA) for single units.

Gas Type

Store Manifold Pressure*

Burner Manifold Pressure

*Recommended Minimum

Natural Gas

7” W.C. / 17.4 mbars / 1.75 kPa

4” W.C. / 10 mbars / 1 kPa

L.P. Gas

13” W.C. / 32.4 mbars / 3.25 kPa

10” W.C. / 25 mbars / 2.5 kPa

Check plumbing/gas codes for proper gas supply line sizing.

Clearance Information

Fryer Front

Fryer Sides, Rear, Bottom

to any combustible material

Fryer Flue Area

All Models

30” (76.2 cm) minimum

6” (15.2 cm)

Do not Curb Mount

Do not block or restrict the flue gasses from flowing into
ventilation system.

ELECTRICAL REQUIREMENTS

Options

Voltage / Phase / Frequency

Amps

Additional Amps for

Filter Heater

Number

of Power Cords

Power

Cord Locations

8.0 GPM (30.3 LPM) 1/3 HP

115 / 1 / 60

7

3

Filter

6.7 GPM (25.4 LPM) 1/3 HP

220-230-240 / 1 / 50

3.6

1.5

1

At filter location

Millivolt controls

Not required

0

N/A

0

No power cord

115 / 1 / 60

1.7

N/A

Fryer

Upgrade controls: Solid state,

Digital, Computer, Basket Lift

220-230-240 / 1 / 50

0.9

N/A

1 cord per 4 fryers

Default is left

GAS REQUIREMENTS

Models

“A” Dim

Cook Area

Oil

Capacity

Gas

Input / Hour

Shipping

Weight / Unit

Shipping

Cube

Shipping Dimensions

H x W x L

SG14

15-5/8 in

39.7 cm

14 x 14 x 4 in

35.6 x 35.6 x 10.2 cm

40 - 50 lbs
18 – 23 kg

110,000 BTU

33 kW (CE) / 119 mJ (AuGA)

200 lbs

91 kg

33 ft.³

.93 m³

58 x 22 ½ x 43 ½ in

147.3 x 57.2 x 110.5 cm

SG14R

15-5/8 in

39.7 cm

14 x 14 x 4 in

35.6 x 35.6 x 10.2 cm

40 - 50 lbs
18 – 23 kg

122,000 BTU

36 kW (CE) / 129 mJ (AuGA)

208 lbs

94 kg

33 ft.³

.93 m³

58 x 22 ½ x 43 ½ in

147.3 x 57.2 x 110.5 cm

SG14T

15-5/8 in

39.7 cm

7 x 14 x 4 in/tank

17.8 x 35.6 x 10.2 cm/tank

20-25 lbs/tank

9-11.5 kg/tank

50,000 BTU/tank

15 kW (CE) / 50 mJ (AuGA)/ tank

230 lbs

104 kg

33 ft.³

.93 m³

58 x 22 ½ x 43 ½ in

147.3 x 57.2 x 110.5 cm

SG18

19-5/8 in

49.8 cm

18 x 18 x 4 ~ 4 ¾ in

45.7 x 45.7 x 10.2 ~12.1

cm

70-90 lbs
32–41 kg

140,000 BTU

40 kW (CE) / 145 mJ ((AuGA)

226 lbs

103 kg

33 ft.³

.93 m³

58 x 22 ½ x 43 ½ in

147.3 x 57.2 x 110.5 cm

SGBNB14

15-5/8 in

39.7 cm

14 ½ x 24 ½ x 4-5/8 in

36.8 x 62.2 x 11.9 cm

N/A

N/A

130 lbs

59 kg

33 ft.³

.93 m³

58 x 22 ½ x 43 ½ in

147.3 x 57.2 x 110.5 cm

SGBNB18

19-5/8 in

49.8 cm

18 ½ x 24 ½ x 4-5/8 in

47 x 62.2 x 11.9 cm

N/A

N/A

150 lbs

68 kg

33 ft.³

.93 m³

58 x 22 ½ x 43 ½ in

147.3 x 57.2 x 110.5 cm

Filter

N/A

N/A

95 lbs

43 kg

N/A

125 lbs / 57 kg

Add 20 lbs (9

kg) per fryer

position

N/A

Ships with

fryer

N/A

SHORT FORM SPECIFICATION

Provide Pitco FD (Filter Drawer) Solstice filter system. Drain line shall be 3” (7.6 cm) diameter with a swivel drain spout for oil disposal. Filter pickup assembly shall have handles
and utilize envelope type filter paper with 500 sq. inches (3,226 sq. cm) of filter area. Filter pump shall pump 8 GPM, 60 Hz (25.4 LPM, 50 Hz). Filter piping to be self-aligning for
easy assembly. Filter lid shall be attached to the cabinet for ease of use. Filter pan shall have front stabilizer legs and rear rigid casters for portability. Provide accessories as
follows:

TYPICAL APPLICATIONS

Space saving filter capable of filtering heavy to light breaded products fast and conveniently.

This manual is related to the following products: