Characteristics, Catv amplifier modules bgy86; bgy87 – Philips BGY87 User Manual
Page 3
1999 Mar 25
3
Philips Semiconductors
Product specification
CATV amplifier modules
BGY86; BGY87
CHARACTERISTICS
Bandwidth 40 to 450 MHz; V
B
= 24 V; T
mb
= 30
°
C; Z
S
= Z
L
= 75
Ω
Notes
1. f
p
= 55.25 MHz; V
p
= 46 dBmV; f
q
= 391.25 MHz; V
q
= 46 dBmV; measured at f
p
+ f
q
= 446.5 MHz.
2. Measured according to DIN45004B: f
p
= 440.25 MHz; V
p
= V
o
; f
q
= 447.25 MHz; V
q
= V
o
−
6 dB;
f
r
= 449.25 MHz; V
r
= V
o
−
6 dB; measured at f
p
+ f
q
−
f
r
= 438.25 MHz.
3. The modules normally operate at V
B
= 24 V, but are able to withstand supply transients up to 30 V.
SYMBOL
PARAMETER
CONDITIONS
MIN.
TYP.
MAX.
UNIT
G
p
power gain
f = 50 MHz
21.5
−
22.5
dB
f = 450 MHz
21.7
−
23.5
dB
SL
slope cable equivalent
f = 40 to 450 MHz
0
−
1.5
dB
FL
flatness of frequency response
f = 40 to 450 MHz
−
−
±
0.2
dB
S
11
input return losses
f = 40 to 80 MHz
20
−
−
dB
f = 80 to 160 MHz
19
−
−
dB
f = 160 to 450 MHz
18
−
−
dB
S
22
output return losses
f = 40 to 80 MHz
20
−
−
dB
f = 80 to 160 MHz
19
−
−
dB
f = 160 to 450 MHz
18
−
−
dB
S
21
phase response
f = 50 MHz
+135
−
+225
deg
CTB
composite triple beat
60 channels flat;
V
o
= 46 dBmV;
measured at 445.25 MHz
BGY86
−
−
−
54
dB
BGY87
−
−
−
58
dB
X
mod
cross modulation
60 channels flat;
V
o
= 46 dBmV;
measured at 55.25 MHz
BGY86
−
−
−
51
dB
BGY87
−
−
−
55
dB
CSO
composite second order distortion
60 channels flat;
V
o
= 46 dBmV;
measured at 446.5 MHz
−
−
−
−
BGY86
−
−
−
53
dB
BGY87
−
−
−
57
dB
d
2
second order distortion
note 1
BGY86
−
−
−
68
dB
BGY87
−
−
−
72
dB
V
o
output voltage
d
im
=
−
60 dB; note 2
BGY86
61.5
−
−
dBmV
BGY87
64
−
−
dBmV
F
noise figure
f = 450 MHz
BGY86
−
−
6
dB
BGY87
−
−
6.5
dB
I
tot
total current consumption (DC)
note 3
BGY86
−
180
200
mA
BGY87
−
220
240
mA