6 redundant backup setting – Planet Technology LCD MONITOR 170S8FS User Manual
Page 16
12
13
Device
LLCF: Link Loss Carry Forward, “on” or “off”.
Enable: to enable the link of the Device, “on” or “off”.
Media 1
LLR: Link Loss Return, “on” or “off”.
Auto: “A” for Auto-Negotiation or “F” for “forced Mode”.
Speed: to select the speed of the copper port, “10M”, “100M” or “1G”.
Dup: Duplex mode, “F” for Full Duplex or “H” for Half Duplex.
FC: Flow Control, “on” or “off”.
Enable: to enable the link of the Media 1, “on” or “off”.
Media 2
LLR: Link Loss Return, “on” or “off”.
Auto: “A” for Auto-Negotiation or “F” for “forced Mode”.
Dup: Duplex mode, “F” for Full Duplex or “H” for Half Duplex.
Enable: to enable the link of the Media 1, “on” or “off”.
Note: Some of the function can be control only depends on the Smart Media
Converter
4.1.3.2.6 Redundant Backup Setting
The redundant function is to change the master line to the slave line in case of the linking
fails happen.
The Redundant functions were set fixed, the master slot is slot 1 (odd number slot) and
the slave slot is slot 2 (even number slot), and there are eight redundant groups in all.
The “Act” will indicate what slot is active.
When the slave slot is active, and we need to transfer again to the master slot, push on
the restart button.