beautypg.com

Pin description (mode 1 – individual overcurrent), Pdiusbh12 usb 2-port hub – Philips Integrated Circuits PDIUSBH12 User Manual

Page 8

background image

Philips Semiconductors

Product specification

PDIUSBH12

USB 2-port hub

1999 Jul 22

8

Pin description (MODE 1 – Individual Overcurrent)

PIN NO

PIN SYMBOL

TYPE

DRIVE

DESCRIPTION

1

TEST1

Input

Connect to V

CC

for 48MHz crystal input.

Connect to Ground for 12MHz crystal input.

2

TEST2

Input

Connect to V

CC

3

TEST3

Input

Connect to Ground

4

RESET_N

Input

ST

Power-on reset

5

GND

Power

Ground reference

6

XTAL1

Input

Crystal connection 1 (48 or 12MHz depending on TEST1 pin)

7

XTAL2

Output

Crystal connection 2 (48 or 12MHz depending on TEST1 pin)

8

CLKOUT

Output

3mA

Programmable output clock for external devices

9

V

CC

Power

Voltage supply 3.3V

±

0.3V

10

OCURRENT2_N

Input

ST

Downstream port 2 over-current notice. This pin is also use to sense the USB
VBUS. A LOW on this pin of less than 2 seconds is interpreted as an overcurrent
notice; longer than 2 seconds is interpreted as loss of VBUS.

11

SWITCH_N

Output

OD6

Enables power to downstream ports

12

SUSPEND

Output

OD6

Device is in suspended state

13

DN2_GL_N

Output

OD6

Downstream port 2 GoodLink

LED indicator

14

OCURRENT3_N

Input

ST

Downstream port 3 over-current notice

15

RSVD

Input

Reserved. Connect to GND for normal operation.

16

RSVD

Input

Reserved. Connect to GND for normal operation.

17

INT_N

Output

OD6

Connect to microcontroller interrupt

18

SDA

I/O

OD6

I

2

C bi-directional data

19

SCL

I/O

OD6

I

2

C bit-clock

20

GND

Power

Ground reference

21

DN3_DP

AI/O

Downstream port 3 D

+

connection

22

DN3_DM

AI/O

Downstream port 3 D

connection

23

DN2_DP

AI/O

Downstream port 2 D

+

connection

24

DN2_DM

AI/O

Downstream port 2 D

-

connection

25

AGND

Power

Analog Ground reference

26

AV

CC

Power

Analog voltage supply 3.3V

±

0.3V

27

UP_DP

AI/O

Upstream D

+

connection

28

UP_DM

AI/O

Upstream D

-

connection

NOTE:
1. Signals ending in _N indicate active low signals.

ST: Schmitt Trigger
OD6: Open Drain with 6 mA drive
AI/O: Analog I/O