COMMAND DESCRIPTIONS

Command Procedure

There are four basic types of commands: Initialization, Data, Hub
Specific, and General commands. Respectively, these are used to
initialize the hub and embedded function; for data flow between the
hub, embedded function, and the host; some hub specific
commands for controlling individual downstream ports; and some
general commands.

Initialization Commands

Initialization commands are used during the enumeration process of
the USB network. These commands are used to enable the hub and
embedded function endpoints. They are also used to set the USB
assigned address.

Set Address / Enable

Command

: D0h (Hub), D1h, D2h, D3h,
(Embedded Functions)

Data

: Write 1 byte

This command is used to set the USB assigned address and enable
the hub or embedded functions respectively. The hub powers up
enabled and needs not be enabled by the firmware at power up
initialization.

7

6

5

4

3

2

0

1

0

0

POWER ON VALUE

ADDRESS

ENABLE

SV00825

0

0

0

0

0

0

Address

The value written becomes the address.

Enable

A ‘1’ enables this function.

Set Endpoint Enable

Command

: D8h

Data

: Write 1 byte

The hub’s interrupt endpoint and the embedded functions generic
endpoints can only be enabled when the corresponding hub/function
is enabled via the Set Address/Enable command.

SV00841

7

6

5

4

3

2

0

1

0

0

POWER ON VALUE

EMBEDDED FUNCTION 1 GENERIC ENDPOINTS

0

0

X

X

X

X

RESERVED

EMBEDDED FUNCTION 7 GENERIC ENDPOINTS

HUB’S INTERRUPT ENDPOINT

EMBEDDED FUNCTION 6 GENERIC ENDPOINTS

Hub’s Interrupt Endpoint

A value of ‘1’ indicates
the hub’s interrupt
endpoint is enabled.

Embedded Function 1 Generic Endpoint

A value of ‘1’ indicates
the embedded function
1 generic endpoints are
enabled.

Embedded Function 6 Generic Endpoint

A value of ‘1’ indicates
the embedded function
6 generic endpoints are
enabled.

Embedded Function 7 Generic Endpoint

A value of ‘1’ indicates
the embedded function
7 generic endpoints are
enabled.

Set Mode

Command

: F3h

Data

: Write 2 bytes

The Set Mode command is followed by two data writes. The first
byte contains the configuration byte values. The second byte is the
clock division factor byte.