Installation, Figure 4a figure 4b 9, Figure 3a figure 3b – Phoenix Gold pm700 User Manual
Page 10: R m s
![background image](/manuals/178711/10/background.png)
model and enough current to allow full-power operation of all the amplifiers plugged into it. The current
demand of a power amplifier varies depending on several factors, including the impedance of the load, the
output level of the amplifier, and the crest factor and duty cycle of the program material. Under typical
conditions reproducing rock music, with both channels driven into a 4 ohm load to the point where musical
peaks are just at the clipping point, the amplifiers require the following average currents:
pm700: 4.3 amps for 120V versions, 2.2 amps for 230V versions
pm900: 6.0 amps for 120V versions, 3.2 amps for 230V versions
Magnetic Leakage Considerations
The pm700 and pm950 may be mounted without concern for magnetic flux leakage, within the confines of
common sense. For example, it’s not a good idea to mount any power amplifier near a microphone input
transformer or magnetic storage media.
Input Wiring
The 1/4-inch phone jacks and XLR connectors for the input signal can be used with either unbalanced 2-conductor
or balanced 3-conductor cables. Use shielded coaxial cable to conduct the signal from the source (i.e. mixer,
equalizer, CD player) to the amplifier.
For balanced operation:
1/4-inch phone jack: Use a 3-conductor TRS 1/4” phone plug. The tip of the plug carries the (+, hot, non-inverting)
side of the signal, the ring carries the (–, low, inverting) side of the signal and the sleeve is ground (see Figure 3A).
XLR: Use a male XLR connector. Pin 2 carries the (+, hot, non-inverting) side of the signal, Pin 3 carries the (–, low,
inverting) side of the signal, and Pin 1 is ground (see Figure 3B).
For unbalanced operation:
1/4-inch phone plug: Use a 2-conductor (Tip-Sleeve) 1/4” phone plug. The tip of the plug carries the signal and the
sleeve is ground. The ring connection in the jack is automatically grounded by the sleeve (see Figure 4A). XLR: Pin
2 carries the (+, hot, non-inverting) side of the signal, and Pin 1 is ground. Short Pin 3 to Pin 1 in order to reference
the input differential amplifier for the correct gain (see Figure 4B). Note: For both amplifiers, the gain remains the
same regardless of whether the input is balanced or unbalanced. Note: The polarity of the balanced inputs can be
reversed by changing four jumpers located on the Input Board. See page 14 for more information.
Input Sensitivity
The input sensitivity of the amplifiers are set at the factory to 1.5V
R M S
for rated output. The input sensitivity can
be changed to 0.775V
R M S
by adding two jumpers on the Main Amplifier Board. See page 14 of this owner’s
manual for more information.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
DO NOT EXPOSE THIS EQUIPMENT
W
MADE
IN
USA
RISK OF HAZARDOUS ENERGY! MAKE PROPER
SPEAKER CONNECTIONS. SEE OPERA
MANUAL BEFORE USING.
WARNING
Serial Number
+
–
GND
FOR BRIDGED
OPERATIONS CONSULT
OWNER'S MANUAL
CLIPPING
ELIMINATOR
BEHIND PANEL
ACTIVATED
1
2
3
+
1
2
3
PUSH
1
2
3
PUSH
INPUT IMPEDANCE 25K OHMS EACH LEG TO GROUND (TOTAL 50K OHMS BALANCED)
SEQUENCE
SND RCV
–
+
GND
(Shield)
–
+
GND
(Shield)
From
Channel 2
From
Channel 1
+
–
GND
FOR BRIDGED
OPERATIONS CONSULT
OWNER'S MANUAL
CLIPPING
ELIMINATOR
BEHIND PANEL
ACTIVATED
1
2
3
+
1
2
3
PUSH
1
2
3
PUSH
INPUT IMPEDANCE 25K OHMS EACH LEG TO GROUND (TOTAL 50K OHMS BALANCED)
SEQUENCE
SND RCV
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
DO NOT EXPOSE THIS EQUIPMENT
W
MADE
IN
USA
RISK OF HAZARDOUS ENERGY! MAKE PROPER
SPEAKER CONNECTIONS. SEE OPERA
MANUAL BEFORE USING.
WARNING
Serial Number
TIP
+
SLEEVE
(Shield)
From
Channel 2
From
Channel 1
TIP
+
SLEEVE
(Shield)
Figure 4A
Figure 4B
9
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
RISK OF HAZARDOUS ENERGY! MAKE PROPER
SPEAKER CONNECTIONS. SEE OPERA
MANUAL BEFORE USING.
INPUT IMPEDANCE 25K OHMS EACH LEG TO GROUND (TOTAL 50K OHMS BALANCED)
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
RISK OF HAZARDOUS ENERGY! MAKE PROPER
SPEAKER CONNECTIONS. SEE OPERA
MANUAL BEFORE USING.