Ak-hc1500goperators manual 12.pdf, Major operating controls and their functions – Panasonic AK-HC1500G User Manual

Page 12

background image

- 11 (E) -

Tally output connector [TALLY OUT]

The R tally and G tally signals are output from this connector.
These signals take effect when the optional card for studio applications has been
inserted.

Pin No.

Signal

1

GND

2

R_TALLY_OUT

3

G_TALLY_OUT

4

+12 V (500 mA Max)

IRIS connector [IRIS]

Used to connect the IRIS control cables of the lens.

Pin No.

Signal

Pin No.

Signal

1

Return control

7

Iris follow

2

VTR-S/S

8

Iris auto selection

3

UNREG GND

9

4

Iris manual selection

10

Zoom position information

5

Iris control

11

Focus position information

6

UNREG 12 V

12

NC

Zoom/Focus connector [ZOOM/FOCUS]

Used to connect the zoom/focus control cables of lens.

Pin No.

Signal

Pin No.

Signal

1

Focus control selection

7

COM

2

Zoom control selection

8

Focus control

3

GND

9

Zoom control

4

Forcible iris closing

10

Iris control selection

5

Iris control

11

COM +Voltage

6

+Voltage

12

COM –Voltage

Operate indicator

Green LED lamp lights to indicate that the specified DC power is supplied to
the DC 12 V input connector .
When the video format is changed, the operate LED flashes twice when the format is
720/60p and once with any other format.

DC 12 V input connector [DC12V IN]

12 V DC is supplied through the optional DC power supply cable (AW-CA4T1).

Major operating controls and their functions