Wire gauge chart – Peavey ICA 600 User Manual
Page 39

WIRE GAUGE CHART
Stranded
Power
Power
Power
Cable
Wire
Loss
Loss
Loss
Length
Gauge
Into
Into
Into
(Feet)
(mm
2
)
8 ohms
4 ohms
2 o
______________________________________________________
5'
1
.79%
1.58%
3.16%
1,5
.5
1.0
2.0
2,5
.31
.62
1.24
4
.20
.40
.80
6
.125
.25
.50
10'
1
1.58%
3.16%
6.32%
1,5
1.0
2.0
4.00
2,5
.62
1.25
2.50
4
.40
.80
1.6
6 .25
.50
1.0
40'
1
8.0%
12.6%
25.2%
1,5
4.0
8.0
16.0
2,5
2.5
5.0
10.0
4
1.60
3.2
6.4
6
1.0
2.0
4.0
10
.625
1.25
2.50
80'
1,5
8.0%
16.0%
32.0%
2,5
5.0
10.0
20.0
4
3.2
6.4
12.8
6
2.0
4.0
8.0
39