beautypg.com

Wire gauge chart – Peavey ICA 600 User Manual

Page 39

background image

WIRE GAUGE CHART

Stranded

Power

Power

Power

Cable

Wire

Loss

Loss

Loss

Length

Gauge

Into

Into

Into

(Feet)

(mm

2

)

8 ohms

4 ohms

2 o

______________________________________________________

5'

1

.79%

1.58%

3.16%

1,5

.5

1.0

2.0

2,5

.31

.62

1.24

4

.20

.40

.80

6

.125

.25

.50

10'

1

1.58%

3.16%

6.32%

1,5

1.0

2.0

4.00

2,5

.62

1.25

2.50

4

.40

.80

1.6

6 .25

.50

1.0

40'

1

8.0%

12.6%

25.2%

1,5

4.0

8.0

16.0

2,5

2.5

5.0

10.0

4

1.60

3.2

6.4

6

1.0

2.0

4.0

10

.625

1.25

2.50

80'

1,5

8.0%

16.0%

32.0%

2,5

5.0

10.0

20.0

4

3.2

6.4

12.8

6

2.0

4.0

8.0

39