beautypg.com

Patton electronic 593/25 User Manual

Page 8

background image

13

14

4.1.5 4-Wire Connection Using DB-25

Most DB-25 connectors on the Model 593/25F conform to EIA-530

interface standards. When connecting to the RS-422/485 devices
which also conform to EIA-530 standards, your cable should have
crossed over wiring, as shown below.

Model 593/TB

RS-485

SIGNAL

DB-25 PIN

DB-25 PIN

SIGNAL

TXA+

2

3

RXA+

TXB-

14 16 RXB-

RXA+

3

2

TXA+

RXB-

16 14

TXB-

4.1.6 2-Wire Connection Using DB-25

Most DB-25 connectors on the Model 593/25F conform to EIA-530

interfaces standards. The RS-422/485 devices also conform to EIA-530
requirements and when connecting these devices, follow the wiring
shown below.

Model 593/25F

RS-485

SIGNAL

DB-25 PIN

SIGNAL

TXA

2

+

TXB

14 -

4.2 OPERATING THE MODELS 593 SERIES

Once the Models 593/25F, 593/45, and 593/TB are properly configured

and installed, it should operate transparently

___

as if it were a standard cable con-

nection. Plug in the external power supply and the units will be powered up.

APPENDIX A

PATTON ELECTRONICS MODEL 593/25, 593/45, and 593/TB

SPECIFICATIONS

Transmission Format:

Asynchronous, full or half duplex

Interface Standard:

RS-422/RS-485

Connectors:

Model 593/25F; DB-25 female on
both sides

Model 593/45; RJ-45 on both sides

Model 593/TB; Terminal block on
both sides

Data Rates:

Up to 115.2 kbps

Power Supply:

External wall-mount transformer,
Regulated +5 VDC @ 120mA

Isolation:

2500 Vrms/optical Isolation

Dimensions:

Model 593/45 & 593/TB
3.8”L x 2.1”W x 0.79”H

Model 593/25
4.1”L x 2.1”W x 0.79H

Temperature Range:

0-60

°

C (32-140

°

F)

Altitude:

0-10,100 feet

Humidity:

5 to 95% noncondensing

This manual is related to the following products: