beautypg.com

Patton electronic 593/25 User Manual

Page 4

background image

5

6

3.0 CONFIGURATION

The Models 593/25F, 593/45, and 593/TB feature configuration via hard-

ware switches and headers. This section describes all possible hardware config-
urations, including the factory default settings. Table 1 below summarizes config-
uration of switches and headers for the Model l 593/25F, 593/45, and 593/TB.

3.1 DIP SWITCH S2 & S3

The Models 593/25F, 593/45, and 593/TB feature two eight-position Dip

switches (S2 and S3). These switches are accessed by opening the plastic
case by inserting a small flat blade screwdriver in the slot on either side of the
case and twisting gently. Figure 1A, below shows Models 593/TB & 593/45
bottom view of the printed circuit board and the location of the dip switches.
Figure 1B shows Model 593/45 bottom view of the printed circuit board and the
location of the DIP switches

The Models 593/25F, 593/45, and 593/TB switches (S2-1 thru S2-8 &

S3-1 thru S3-8) can be configured as either “On” or “Off”. Figure 2 shows the
orientation of the DIP switches with respect to ON/OFF positions.

3.1.1 Configuration DIP Switches Sets S2 and S3

The two eight-position Dip switches are used to configure the units for

common asynchronous data rates, full or half duplex over 2-wire/4-wire twisted
pair. The following sections describe all the possible configurations.

Figure 2. Close up of DIP switches showing ON/OFF positions.

The switch is shown in the Off position.

NOTE:

When selecting any hardware configurations

below, Switch S2 and Switch S3 must be set the same.

S3

ON

OFF

S2

ON

OFF

Figure 1B. Model 593/25, location of S2 &

S3 on Printed Circuit Board

S2

ON

OFF

S3

ON

OFF

Figure 1A. Models 593/TB & 593/45, location

of S2 & S3 on Printed Circuit Board

Position Function ON/OFF Full Duplex Half Duplex Half Duplex

S2-1

TX Mode

HD/FD

OFF

ON

ON

S2-2

Operation

422/485

ON

OFF

OFF

S3-1

TX Mode

HD/FD

OFF

ON

ON

S3-2

Operation

422/485

ON

OFF

OFF

S1-1,2

Interface

2W/4W

OFF

ON

OFF

S1-3

RX IMP.

120 /HI

ON

ON

ON

S1-4

Not Used ( )

X

X

X

S4-1, 2

Interface

2W/4W

OFF

ON

OFF

S4-3

RX IMP.

120 /HI

ON

ON

ON

S4-4

Not Used

( )

X

X

X

Table 1. Configuration summary of swithes and headers

Switch

Mode

422 4W 485 2W 485 4W

Typical Application Settings

3.1.2 Full/Half Duplex S2-1 and S3-1

Switches S2-1 and S3-1 determine full duplex or half duplex trans-

mission mode.

3.1.3 422/485 Operation S2-2 and S3-2

Switches S2-2 and S3-2 determine RS-422 or RS-485 interface

operation.

Half Duplex

Full Duplex

S2-1 ON

OFF

S3-1

ON

OFF

RS-422

RS-485

S2-2 ON

OFF

S3-2

ON

OFF

This manual is related to the following products: