4.1.2 2-Wire Connection Using RJ-45

Most RS-485 devices employ a two-wire, half duplex configuration.

When using this configuration, be sure to first set the Model 593/45 to
half duplex mode by switching DIP switches and jumpers (refer to sec-
tion 3.0 for this configuration)—then use

only the transmit (XMT) pair

as shown below

593/45 SIGNAL

RS-485 SIGNAL

XMT+ ....................................+
XMT- .....................................-

4.1.3 4-Wire Connection Using Terminal Blocks

If you purchased the Model 593/TB, you will need to open the

case to access the terminal blocks. The following instructions will tell
you how to open the case, connect the bare wires to the terminal
blocks, and fasten the strain relief collar in place so that the wires
won't pull loose.

1. If the case is not already open, open it now by twisting it open

with a small plastic screwdriver.

2. Strip the outer insulation from the twisted pairs about one inch

from the end.

3. Strip back the insulation on each of the 2 twisted pair wires

about .25 inch.

4. Place the cable through the end plate, and make a small loop

in the cable and feed the cable under the tie wrap which is cur-
rently installed in the board. When you have completed this
assembly it should resemble figure figure 5. Connect

one pair

of wires to XMT+ and XMT- (transmit positive and negative)
on the terminal block, making careful note of which color is

positive, and which color is negative.

5. If you are using 4-wire mode, connect the other pair of wires to

RCV+ and RCV- (receive positive and negative) on both of the
terminal blocks, again making careful note of which color is
positive, and which is negative.

Ultimately, you will want to construct a four pair cross over cable

that makes a connection with the RS-422/485 device, as shown below.

Model 593/TB

RS-422/-485 Device

SIGNAL

TERMINAL BLOCK

SIGNAL

TXB+

TB (5) RXB+

TXA-

TB (4) RXA-

RXB+

TB (1) TXB+

RXA-

TB (2) TXA-

4.1.4 2-Wire Connection Using Terminal Blocks

Most RS-485 devices employ a two-wire, half duplex configuration.

When using this configuration, be sure to first set the Model 593/TB to
half duplex mode by switching DIP switches and jumpers (refer to sec-
tion 3.0 for this configuration)—then use

only the transmit (XMT) pair

as shown below

Model 593/TB

RS-485 Device

XMT+ .......................... +
XMT- ............................ -

Figure 5. Model 593/TB, showing Terminal Block & Cable Routing