Service replacement parts, Service and repairs, Troubleshooting guide – Porter-Cable N030679 User Manual
Page 29

29 - ENG
SERVICE
REpLACEmENT pARTS
Use only identical replacement parts. You can also order parts from your nearest
service center.
SERVICE AND REpAIRS
All quality tools will eventually require servicing and/or replacement of parts. All
repairs made by our service centers are fully guaranteed against defective material
and workmanship. We cannot guarantee repairs made or attempted by others.
TROUBLEShOOTING GUIDE
This section provides a list of the more frequently encountered malfunctions,
their causes and corrective actions. The operator or maintenance personnel can
perform some corrective actions, and others may require the assistance of a
qualified PORTER CABLE technician or your dealer.
problem
Code
Engine will not start ........................... 1, 2, 3, 4, 14, 15, 16, 17, 18, 19, 20, 21, 27
No electrical output ............................................................... 5, 6, 7, 8, 9, 10, 12, 13
NOTE: If there is still no power at the receptacles, Contact a Customer Care
Center.
Repeated main breaker tripping ......................................................................... 9, 10
Generator overheating ........................................................................................ 9, 11
Engine does not continue to run after starting ..1, 2, 3, 14, 16, 18, 19, 20, 21, 27
Knocking noise ....................................................................................................23
Over speed or low speed ....................................................................... 24, 25, 26
Low power ........................................................................................ 16, 19, 22, 23
CODE pOSSIBLE CAUSE
pOSSIBLE SOLUTION
1
Engine On/Off switch in OFF
position.
Turn to ON position
2
Choke in wrong position
Adjust choke accordingly
3
Fuel shut-off valve in closed
position
Open fuel shut-off valve
4
Unit loaded during start-up
Remove load from unit
5
Faulty receptacle
Contact a Customer Care Center.
6
Receptacle thermal circuit
breaker tripped
Depress and reset
7
Defective capacitor
Contact a Customer Care Center.
8
Faulty power cord
Repair or replace cord
9
Generator overloaded
Reduce load
10
Faulty cords or equipment
Check for damaged, bare or frayed
wires on equipment. Replace.
11
Insufficient ventilation
Move to adequate supply of fresh air
12
Faulty windings in stator
Contact a Customer Care Center.
13
Faulty wire harness
Contact a Customer Care Center.
14
Low or no fuel
Add fuel
15
Bad fuel
Drain fuel tank and replace with fresh,
clean, regular unleaded gasoline
with a minimum of 86 octane
16
Low oil
Add oil