61

8 INITIAL SETTING

8-10 Initial Setting 5

1. Selection of Transfer rate (baud rate) : [BAUD UNIT]

Select a baud rate of 1200, 2400, 4800, or 9600.

2. Selection of Data bits : [DATA LENGTH]

Select a data length of 8 bits or 7 bits.

3. Selection of Parity : [PARITY BITS]

Select no (NIL) parity bit, even parity, or odd parity.

4. Selection of Stop bit : [STOP BITS]

Select the number of stop bits to be used: 1 or 2.

5. Selection of Control signal : [SIGNAL CONTROL]

Select whether the control signal is effective or not.

6. Selection of XON/XOFF : [XON/XOFF]

Select whether to enable or disable XON/XOFF.

7. Selection of Through command : [THROUGH

COMMAND]
Select whether to disable data output without receiving
any data request command or enable the “a” to “f”
command data output.

1. 1200

2. 2400

3. 4800

4. 9600

1. 8

2. 7

1. NIL

2. EVEN

3. ODD

1. 1

2. 2

1. ON

2. OFF

1. ON

2. OFF

1. NIL

2. a

3. b

4. c

5. d

6. e

7. f