beautypg.com

Python Model 902 User Manual

Page 33

background image

28

© 2 0 0 6 d i r e c t e d e l e c t r o n i c s

faulty door pin switches or environmental conditions such as
thunder, jackhammers, airport noise, etc.

Example

If the alarm triggers three times within a 60-minute period and
each time the same sensor or switch triggers the alarm, NPC

®

will

interpret those triggers as false alarms. After the third trigger,
NPC

®

ignores, or bypasses, that sensor or switch (along with any

other sensors or switches sharing the same zone) for 60 minutes.

If the bypassed sensor tries to trigger the system while it is being
bypassed, the 60-minute bypass period will start over. This ensures
that a sensor that continually triggers will remain bypassed.

Doors are covered by NPC

®

differently; if the alarm is triggered

by an open door for three full cycles, the doors will be bypassed
until the trigger ceases.

NPC

®

is On/Off programmable. See your dealer and the

Programming section of this guide for more information.

note: Arming and disarming the system does not reset this
function. In order to reset a bypassed zone, the same zone
must not trigger for 60 minutes, or ignition is turned on.
If testing your system, it is important to remember that the
NPC

®

programming can cause zones to be bypassed and

appear to stop working. If five chirps are heard when dis-
arming, NPC

®

has been engaged. If you wish to clear the

NPC

®

memory, turn the ignition key on.