beautypg.com

Approximate lumen maintenance, Approximate survival curve, Ceramalux – Philips P-5781-B User Manual

Page 2: High pressure sodium non-cycling

background image

0

60

80

70

90

100

%

P

e

rc

e

n

t

A

p

p

ro

x

.S

u

rv

iv

al

0

20

40

60

80

100

(0)

(6,000)

(12,000)

(18,000)

(24,000)

(30,000)

0

20

40

60

80

100

(0)

(6,000)

(12,000)

(18,000)

(24,000)

(30,000)

Percent of Rated Average Life

(Lamp Operating Hours)

Percent of Rated Average Life

(Lamp Operating Hours)

0

60

80

70

90

100

%

P

e

rc

e

n

t

A

p

p

ro

x

.S

u

rv

iv

al

0

20

40

60

80

100

(0)

(6,000)

(12,000)

(18,000)

(24,000)

(30,000)

0

20

40

60

80

100

(0)

(6,000)

(12,000)

(18,000)

(24,000)

(30,000)

Percent of Rated Average Life

(Lamp Operating Hours)

Percent of Rated Average Life

(Lamp Operating Hours)

Approximate Lumen Maintenance

Ceramalux

®

High Pressure Sodium Non-Cycling

Approximate Survival Curve

Ceramalux

®

High Pressure Sodium Non-Cycling

© 2008 Philips Lighting Company. All rights reserved.
Printed in USA 2/08

P-5781-B

www. philips.com

Philips Lighting Company
200 Franklin Square Drive
P.O. Box 6800
Somerset, NJ 08875-6800
1-800-555-0050

A Division of Philips Electronics North America Corporation

Philips Lighting
281 Hillmount Road
Markham, Ontario
Canada L6C 2S3
1-800-555-0050

A Division of Philips Electronics Ltd.

Ceramalux

®

High Pressure Sodium Non-Cycling Lamps featuring ALTO

®

Lamp Technology

Ordering, Electrical and Technical Data

Rated

Approx

Approx

Color

Product

ANSI

Nom.

Pkg.

Bulb

LCL

MOL

Avg. Life

Initial

Mean

Temp.

Number Ordering Code

Code

Watts

Bulb

Base

Qty.

Finish

(In.)

(In.)

(Hrs.)

1

Lumens

2

Lumens

3

(Kelvin)

4

20224-2

C50S68/ALTO NC HPS

S68

50

ED23

1

2

Mogul

20

Clear

5

7

3

4

30,000

4000

3600

2100

14739-7

C70S62/ALTO NC HPS

S62

70

ED23

1

2

Mogul

12

Clear

5

7

3

4

30,000

6300

5670

2100

14740-5

C100S54/ALTO NC HPS

S54

100

ED23

1

2

Mogul

12

Clear

5

7

3

4

30,000

10,000

9000

2100

14741-3

C150S55/ALTO NC HPS

S55

150

ED23

1

2

Mogul

12

Clear

5

7

3

4

30,000

16,000

14,400

2100

15725-5

C200S66/ALTO NC HPS

S66

200

ED18

Mogul

12

Clear

5

3

4

9

3

4

30,000

22,000

19,800

2100

14742-1

C250S50/ALTO NC HPS

S50

250

ED18

Mogul

12

Clear

5

3

4

9

3

4

30,000

28,500

25,650

2100

14743-9

C400S51/ALTO NC HPS

S51

400

ED18

Mogul

12

Clear

5

3

4

9

3

4

30,000

50,000

45,000

2100

15726-3

C1000S52/ALTO NC HPS

S52

1000

ED25

Mogul

6

Clear

8

3

4

15

1

16

30,000

130,000

117,000

2100

1) Rated average life is the life obtained, on the average, from large representative groups of lamps in laboratory tests under controlled conditions at 10 or more

operating hours per start. It is based on survival of 65% of the lamps and allows for individual lamps or groups of lamps to vary considerably from the average.

2) Approximate lumen values listed are for vertical or horizontal operation of lamp.

3) Approximate mean lumen output at 40% of lamp rated average life.

4) Approximate color temperature in Kelvin degrees.

Above specifications subject to change without notice.

Footnotes from front:

* Rated average life is the life obtained, on the average, from large representative groups of lamps in laboratory tests under controlled conditions at 10 or more operating hours per start.

It is based on survival of 65% of the lamps and allows for individual lamps or groups of lamps to vary considerably from the average.

† The TCLP is the US EPA’s Toxicity Characteristic Leaching Procedure. Check state and local regulations regarding non-hazardous waste.
◊ Higher lumen output for 50, 100, 150, 200, and 250 watts and equivalent for 400W, and less for 1000W.

RECOMMENDED WARNINGS, CAUTIONS,AND OPERATING INSTRUCTIONS

R

“WARNING: These lamps must be operated in fixtures designed for use with High Pressure Sodium
lamps.The fixture wattage rating must match the wattage indicated on the outer glass bulb. Do not scratch

the outer bulb or subject it to pressure as this could cause the outer bulb to crack or shatter. A partial vacuum in
the outer bulb may cause glass to fly if the glass is struck. Operating the lamp improperly may result in
PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE.

1) If the outer glass bulb is broken, shut off power immediately and remove the lamp after it has cooled.

2) Use only auxiliary equipment meeting Philips and/or ANSI standards. Use within voltage limits recommended

by ballast manufacturer.

A. Operate lamp only within specified limits of operation.

B. For total supply load refer to ballast manufacturers electrical data.

3) Protect lamp base, socket and wiring against moisture, corrosive atmospheres and excessive heat.

4) Replace the lamp if the outer glass bulb has been scratched, cracked or damaged in any way.

5) If a lamp bulb support is used, be sure to insulate the support electrically so as to avoid possible decomposition

of the bulb glass.

6) Do not use this lamp in a fixture which redirects a substantial portion of the energy toward the arc tube and its

immediate vicinity, as this may lead to very early lamp failure.

7) Take care in handling and disposing of lamps. If arc tube is broken, avoid skin contact with any of the

contents or fragments.

8) The arc tube of this lamp contains sodium and mercury. Dispose of in accordance with federal, state

and local requirements.