Approximate lumen maintenance, Approximate survival curve, Ceramalux – Philips P-5781-B User Manual
Page 2: High pressure sodium non-cycling
0
60
80
70
90
100
%
P
e
rc
e
n
t
–
A
p
p
ro
x
.S
u
rv
iv
al
0
20
40
60
80
100
(0)
(6,000)
(12,000)
(18,000)
(24,000)
(30,000)
0
20
40
60
80
100
(0)
(6,000)
(12,000)
(18,000)
(24,000)
(30,000)
Percent of Rated Average Life
(Lamp Operating Hours)
Percent of Rated Average Life
(Lamp Operating Hours)
0
60
80
70
90
100
%
P
e
rc
e
n
t
–
A
p
p
ro
x
.S
u
rv
iv
al
0
20
40
60
80
100
(0)
(6,000)
(12,000)
(18,000)
(24,000)
(30,000)
0
20
40
60
80
100
(0)
(6,000)
(12,000)
(18,000)
(24,000)
(30,000)
Percent of Rated Average Life
(Lamp Operating Hours)
Percent of Rated Average Life
(Lamp Operating Hours)
Approximate Lumen Maintenance
Ceramalux
®
High Pressure Sodium Non-Cycling
Approximate Survival Curve
Ceramalux
®
High Pressure Sodium Non-Cycling
© 2008 Philips Lighting Company. All rights reserved.
Printed in USA 2/08
P-5781-B
www. philips.com
Philips Lighting Company
200 Franklin Square Drive
P.O. Box 6800
Somerset, NJ 08875-6800
1-800-555-0050
A Division of Philips Electronics North America Corporation
Philips Lighting
281 Hillmount Road
Markham, Ontario
Canada L6C 2S3
1-800-555-0050
A Division of Philips Electronics Ltd.
Ceramalux
®
High Pressure Sodium Non-Cycling Lamps featuring ALTO
®
Lamp Technology
Ordering, Electrical and Technical Data
Rated
Approx
Approx
Color
Product
ANSI
Nom.
Pkg.
Bulb
LCL
MOL
Avg. Life
Initial
Mean
Temp.
Number Ordering Code
Code
Watts
Bulb
Base
Qty.
Finish
(In.)
(In.)
(Hrs.)
1
Lumens
2
Lumens
3
(Kelvin)
4
20224-2
C50S68/ALTO NC HPS
S68
50
ED23
1
⁄
2
Mogul
20
Clear
5
7
3
⁄
4
30,000
4000
3600
2100
14739-7
C70S62/ALTO NC HPS
S62
70
ED23
1
⁄
2
Mogul
12
Clear
5
7
3
⁄
4
30,000
6300
5670
2100
14740-5
C100S54/ALTO NC HPS
S54
100
ED23
1
⁄
2
Mogul
12
Clear
5
7
3
⁄
4
30,000
10,000
9000
2100
14741-3
C150S55/ALTO NC HPS
S55
150
ED23
1
⁄
2
Mogul
12
Clear
5
7
3
⁄
4
30,000
16,000
14,400
2100
15725-5
C200S66/ALTO NC HPS
S66
200
ED18
Mogul
12
Clear
5
3
⁄
4
9
3
⁄
4
30,000
22,000
19,800
2100
14742-1
C250S50/ALTO NC HPS
S50
250
ED18
Mogul
12
Clear
5
3
⁄
4
9
3
⁄
4
30,000
28,500
25,650
2100
14743-9
C400S51/ALTO NC HPS
S51
400
ED18
Mogul
12
Clear
5
3
⁄
4
9
3
⁄
4
30,000
50,000
45,000
2100
15726-3
C1000S52/ALTO NC HPS
S52
1000
ED25
Mogul
6
Clear
8
3
⁄
4
15
1
⁄
16
30,000
130,000
117,000
2100
1) Rated average life is the life obtained, on the average, from large representative groups of lamps in laboratory tests under controlled conditions at 10 or more
operating hours per start. It is based on survival of 65% of the lamps and allows for individual lamps or groups of lamps to vary considerably from the average.
2) Approximate lumen values listed are for vertical or horizontal operation of lamp.
3) Approximate mean lumen output at 40% of lamp rated average life.
4) Approximate color temperature in Kelvin degrees.
Above specifications subject to change without notice.
Footnotes from front:
* Rated average life is the life obtained, on the average, from large representative groups of lamps in laboratory tests under controlled conditions at 10 or more operating hours per start.
It is based on survival of 65% of the lamps and allows for individual lamps or groups of lamps to vary considerably from the average.
† The TCLP is the US EPA’s Toxicity Characteristic Leaching Procedure. Check state and local regulations regarding non-hazardous waste.
◊ Higher lumen output for 50, 100, 150, 200, and 250 watts and equivalent for 400W, and less for 1000W.
RECOMMENDED WARNINGS, CAUTIONS,AND OPERATING INSTRUCTIONS
R
“WARNING: These lamps must be operated in fixtures designed for use with High Pressure Sodium
lamps.The fixture wattage rating must match the wattage indicated on the outer glass bulb. Do not scratch
the outer bulb or subject it to pressure as this could cause the outer bulb to crack or shatter. A partial vacuum in
the outer bulb may cause glass to fly if the glass is struck. Operating the lamp improperly may result in
PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE.
1) If the outer glass bulb is broken, shut off power immediately and remove the lamp after it has cooled.
2) Use only auxiliary equipment meeting Philips and/or ANSI standards. Use within voltage limits recommended
by ballast manufacturer.
A. Operate lamp only within specified limits of operation.
B. For total supply load refer to ballast manufacturers electrical data.
3) Protect lamp base, socket and wiring against moisture, corrosive atmospheres and excessive heat.
4) Replace the lamp if the outer glass bulb has been scratched, cracked or damaged in any way.
5) If a lamp bulb support is used, be sure to insulate the support electrically so as to avoid possible decomposition
of the bulb glass.
6) Do not use this lamp in a fixture which redirects a substantial portion of the energy toward the arc tube and its
immediate vicinity, as this may lead to very early lamp failure.
7) Take care in handling and disposing of lamps. If arc tube is broken, avoid skin contact with any of the
contents or fragments.
8) The arc tube of this lamp contains sodium and mercury. Dispose of in accordance with federal, state
and local requirements.