beautypg.com

Pitco Frialator Solstice supreme with Matchless Ignition (Built after 08/2000) User Manual

Page 32

background image

TROUBLESHOOTING

32

L20-378 rev.3 (01/13)

1- SCBS Reset Button


3.5. RESETTING THE SELF CLEANING BURNER SYSTEM TEMPERATURE LIMIT SWITCH

1. Turn the appliance off.

2. Allow the appliance ample time to cool to room

temperature.

3. Press the SCBS high limit reset button. The reset

button is located behind the front panel at the top
of the main burners.

4. The SCBS high limit switch is now reset and

ready for startup.

5. If the SCBS high temperature limit switch

continues to trip, have the appliance inspected by
an Authorized Professional.




















Event Duration

Indication

Turn appliance “ON”

N/A

Control Illuminates, pilot sparks and ignites. Pre-Purge
pulse is initiated.

Pre-Purge Pulse

2 seconds

Appliance operates briefly and stops. Pilot remains lit.

Interwaiting period 1

5 seconds

Appliance does not operate. Pilot remains lit.

Cleaning Pulse

6 seconds

Main valve operates, lighting main burners. SCBS valve
operates, feeding gas to the SCBS Arm. The SCBS arm
ignites, initiating a brief burn at the main burner orifice of
each burner.

Interwaiting period 2

8 seconds

The Main and SCBS valves de-energize for this period.
The pilot remains lit.

Normal operation
resumes

N/A

The appliance operates normally and begins to heat up.
The SCBS Valve remains de-energized until power to
the appliance is recycled. There is no flame on the
SCBS Arm. There is no burn at the main burner orifices.