Proxima ASA 7911 User Manual
Page 88
82
The StatusInd field does not show whether the destination node
has received the message.
Message Format:
BYTE
response (ASCII ‘t’, 74H)
BYTE
seqno
(from original command)
BYTE
len H
(from original command)
BYTE
len L
(from original command)
BYTE
destaddr H
(from original command)
BYTE
destaddr 3
(from original command)
BYTE
destaddr 2
(from original command)
BYTE
destaddr L
(from original command)
BYTE
StatusInd
The valid values of the StatusInd field are as follows:
00H: Successful Transmission to the TCP/IP stack
01H: Transmission Error
Signal Strength Report
Purpose: This packet is generated by the Serial Adapter in re-
sponse to a Request Radio Signal Strength command. The packet
contains the signal strength value for the Serial Adapter’s current
radio channel. The signal strength value range from 00H to FFH.
A value of FFH signifies maximum signal strength.
Message Format:
BYTE
response (ASCII ‘r’, 72H)
BYTE
seqno (from original command)
BYTE
Signal strength on current channel