163

[Reference]

Reference

Example of Data Communication

Example of Changing Parameters

The following illustrates time-series communications data flow when a change is made to a parameter.

Communications should be conducted in the sequence of outline, (1) individual writing of parameters and (2) writing

to EEPROM if storage is needed. In this example of hardware connection, the device is directly connected with a

host through RS232C communications with user ID=1. Data is represented in hexadecimals.

(Note) For details of commands, refer to “List of Communications Commands” on Page 166.

(1) Individual Writing of Parameters

(2) Writing of Parameters to EEPROM

Host

04

06

(EOT)

(ACK)

05

03

01

18

0B

00

00

D9

(ENQ)

(ACK) (ENQ)

MINAS-E(1)

Host

05

01

01

18

00

E6

04

(ENQ)

(EOT)

04

06

05

00

01

48

(EOT)

(ACK) (ENQ)

MINAS-E(1)

Host

06

05

01

01

48

00

B6

B7

04

06

(EOT)

(ACK)

MINAS-E(1)