beautypg.com

Milnor BICWUT01 User Manual

Page 9

background image

PELLERIN MILNOR CORPORATION

b. Calculate the desired counts for a basket speed of 24 RPMs:

C

d

= [RPM

d

* (C/RPM)] + D

C

d

= [24 RPMs * (6 counts per RPM)] + 15

159 = 144 + 15

c. Calculate the desired voltage:

V

d

= C

d

/ 409.5

0.3883 = 159 / 409.5

2. The DC voltage measured at the output terminals of the D-to-A board and at analog voltage

input terminals FV and FC on the inverter (shown in Figure 2) should match this number.

You may see a small voltage drop from the D-to-A board to the inverter.

Figure 2: Measuring Control Voltage at D-to-A Board and Inverter

Digital-to-Analog Board

Legend

A.

MTA-43 Pin 3

B.

MTA-43 Pin 8

C.

Inverter terminal A1

D.

Inverter terminal AC

E.

Inverter terminal FV

F.

Inverter terminal FC

Inverter Analog Terminals for Yaskawa F7

Inverter Analog Terminals for Yaskawa GPD 506

.

3. If this value is wrong at the D-to-A board, replace the board.