APPENDIX A

SPECIFICATIONS

Transmission Format: Synchronous, full duplex

Transmission Line: Two unconditioned twisted pair 19 - 26 AWG

Range: (See table below)

Interfaces: EIA RS-232, CCITT V.24

Data Rates: 1200 - 19.2 Kbps

Isolation: Minimum 1500 V RMS via custom transformers

Surge Protection: 600W Surge Protection (10x1000µs waveform)

(Model 1020S)

Control Signals: CTS turns on 7 or 53 mS (switch selectable)

after the terminal raises RTS; DSR and DCD are constantly on

Connectors: DB-25 male or female on RS-232 side;

RJ-11, RJ-45 or terminal block with strain relief on line side

Power Supply: None required; uses power from EIA data and

control signals

Temperature Range: 0-60°C (32-140°F)

Altitude: 0-15,000 feet

Humidity: Up to 95% non-condensing

Weight: 2 oz.

Dimensions: 2.66” x 2.10” x 0.73”

10. BEND the top half of the case as necessary to place it over the

strain relief assembly. Do not snap the case together yet.

11. Insert one captive screw through a saddle washer and then

insert the entire piece through the hole in the DB-25 end of the
case. Snap that side of the case closed. Repeat the process
for the other side. This completes cable installation.

4.2 CONNECTION TO THE RS-232 INTERFACE

Once you have connected the twisted pair wires correctly, simply

plug the Model 1020 directly into the DB-25 port of the RS-232 device.
After doing so, remember to insert and tighten the two captive
connector screws.

(Note: If you must use a cable to connect the Model 1020 to the

RS-232 device, make sure it is a

straight through

cable of the shortest

possible length—we recommend 6 feet or less).

4.3 OPERATING THE MODEL 1020

Once the Model 1020 is properly configured and installed, it should

operate transparently—as if it were a standard cable connection.
Operating power is derived from the RS-232 data and control signals;
there is no “ON/OFF” switch. All data signals from the RS-232 interface
are passed straight through. All control signals from the RS-232
interface are looped back.

NOTE: If your system requires

hardware

flow control, you will

need the Patton Model 1030 or Model 1070 Short Range Modem.
Call Patton Customer Service at 301-975-1007 for more
information.

11

12

Data
Rate

Wire Gauge

19

24

26

19,200

7.5

3.5

2.5

9,600

10.0

3.5

2.5

4,800

10.0

7.0

4.0

2,400

10.0

8.5

5.0

1,200

11.0

8.5

6.0

Model 1020 Distance Table (miles)