3 access control, Access control – Planet Technology 8-Port IP Power Manager IPM-8001 User Manual
Page 47
firmware.
Telnet Connection
This is the parameter enabling or disabling the terminal to the server
application (Telnet) control process. (e.g. telnet 192.168.1.1). The
user may configure the Telnet protocol to use a port number other
than the standard Telnet port (23).
HTTP Support
Enable/Disable the HTTP connection with the IP Power Manager.
The user may configure HTTP protocol to use a port number other
than standard HTTP port (80).
SNMP Support
Enable/Disable the SNMP connection with the IP Power Manager.
The user may configure the SNMP protocol to use a port number other
than the standard SNMP port (161).
6.4.3 Access
Control
Configuration of this page is allowed when the security level is “Administrator”. It prevents
unauthorized network access to the IP Power Manager. There are 2 kinds of type for "Access
Type", "Permitted", and "Denied". It is need to set the first item for its "IP Address" to
"255.255.255.255" and "Access Type" to "Permitted" as default value in order to let user is
able to connect to the IP Power Manager.
- 33 -
Option
Description
Index
The index number of the entry in the table.
IP Address
The management station's IP address. "0.0.0.0" means entry not
configured. (e.g. An entry "192.168.7.255" means the client with the
IP address within the range from "192.168.7.0" to "192.168.7.255"