beautypg.com

Patton electronic 1140RC User Manual

Page 10

background image

APPENDIX A

SPECIFICATIONS

Transmission Line: Dual optical cable

Transmission Mode: Asynchronous, half or full duplex, point-to-point

Interfaces: EIA RS-232, CCITT V.24

Data Rates: 0 - 57.6 Kbps

Distance: 2 miles over continuous fiber

RTS/CTS Delay: Switch-selectable: No delay, 7.0 mS, 53 mS

Receiver Sensitivity: -45 dBm

Coupled Power Output: -30 to -36 dBm

Optic Wavelength: 850 nm

LED Indicators: Power, TD, RD, RTS, CD, Test Mode, Error

Connectors: HD-26 female on RS-232 side; ST or SMA connectors

on fiber side

Power Supply: 120/240V (switchable) on rack chassis

Temperature Range: 0-60°C (32-140°F)

Altitude: 0-15,000 feet

Humidity: Up to 95% non-condensing

Weight: 2 oz.

Dimensions: 0.95”W x 3.1”H x 5.4”L

17

18

1.

Locate the lower of the two toggle switches on the front panel
of the Model 1140RC and move it to the right. This will
activate the V.52 BER test mode and transmit a “511” test
pattern to the other unit. If any errors are present, the
receiving modem’s red “Error” LED will blink sporadically.
Note: For this independent test to function, the “511” switch on

both

Model 1140RCs must be turned on.

2.

If the test indicates no errors are present, move the V.52
toggle switch to the left, thus activating the “511/E” test with
periodic errors present. If the test is working properly, the
receiving modem’s red “Error” LED will blink

regularly

. A

successful “511/E” test will confirm that the link is in place, and
that the Model 1140RC’s built-in “511” generator and detector
are working properly.