Pre-season Inspection

Clean the air filters, re-insert and operate the air

conditioners.

Is the discharged air cold / warm?

Operation is normal if 15 minutes after the start of
operation, the difference between the air intake and
outlet vents temperature is:-

Are the air intake or outlet vents of the indoor or

outdoor units obstructed?

Are the remote control batteries weak?

If the remote control display appears weak, replace
the batteries.

When the Air Conditioner is Not Used

for an Extended Period of Time

1

To dry the internal parts of the indoor unit, operate
the unit for 2 - 3 hours using:-

2

Turn off the power supply and unplug.

3

Remove the remote control batteries.

Recommended Inspection

• After used over several seasons, the unit will become

dirty and thus decreases the unit’s performance.
Depending on the operation conditions, a dirty unit
may produce odour and dust may pollute
dehumidification system. Therefore, a seasonal
inspection is recommended in addition to regular
cleaning. (Consult an authorized dealer).

Cooling Model

FAN operation

Heat Pump Model

COOL operation with
30°C set temperature

Cooling Model

COOL –> 8°C or above

Heat Pump Model

COOL –> 8°C or above

HEAT –> 14°C or above

HELPFUL INFORMATION

Auto Operation

Automatic Operation

• If the remote control fails to function or has been

misplaced, press the Auto Operation button to start
the Automatic operation.

• The Automatic operation will be activated

immediately once the Auto operation button is
pressed. However, temperature cannot be adjusted
in this operation.

• The power indicator on the indoor unit will blink until

the operation mode is selected automatically.

• To cancel this operation, press once more.

Timer Setting

• When power failure occurs, the timer setting will be

cancelled. Once power is resumed, reset the timer.

Thunder and Lightning

• This air conditioner is equipped with a built-in surge

protective device. However, in order to further
protect your air conditioner from being damaged by
abnormally strong lightning activity, you may switch
off the main power supply and unplug from power
socket.

Auto Restart Control

• If power is resumed after a power failure, the

operation will restart automatically after 3 - 4
minutes.

• Operation will be restarted automatically under the

previous operation mode and airflow direction when
power is resumed as the operation is not stopped
by the remote control.

ENERGY SAVING AND OPERATION
HINTS

Setting the Temperature

• Approximately 10% of electricity can be saved.
• Set the temperature higher or lower than the

desired temperature.

Cooling Model

Cooling Operation : 1°C higher

Heat Pump Model

Cooling Operation : 1°C higher
Heating Operation : 2°C lower

Air Filters

• Clean the air filters every 2 weeks.
• Dirty filters may reduces cooling or heating

efficiency.

Keep All Doors and Windows Closed

• Otherwise, cooling or heating performance will be

reduced and electricity cost is wasted.

Outdoor Unit

• Do not block the air outlet vents. Otherwise, it will

lower the cooling or heating performance.

Timer and Sleep Mode

• To prevent wastage of electricity, use sleep mode

when sleeping or Timer when going out.

Avoid Direct Sunlight

• Keep curtains or drapes closed to avoid direct

sunlight during cooling operation.

Press the Auto

Operation Button

AUTO OFF/ON

Call the Dealer Immediately

If the following conditions occur, turn off and unplug the
main power supply, and then call the dealer immediately.

Abnormal noise is heard during operation.

Water or foreign material gets into the remote
control by mistake.

Water leak from the indoor unit.

Switches or buttons do not operate properly.

The circuit breaker switches off frequently.

Power supply cord and plug become unusually
warm.

TROUBLESHOOTING

Normal Operation

Is it okay?

• Air conditioner has been restarted, but does not

operate for 3 minutes.

• A sound like water flowing can be heard.

• It seems that fog is coming out from the air

conditioner.

• The room has a peculiar odour.

• The outdoor unit emits water or steam.

• During Automatic Airflow Volume setting,

indoor fan stops occasionally.

• (For Heat Pump Model only)

Operation stops for about 12 minutes during
heating (The power indicator blinks).

• (For Heat Pump Model only)

During heating operation, indoor fan may
run at on and off conditions.

Abnormal Operation

Is it okay?

• The air conditioner does not operate.

• Air conditioner produces loud noise during

operation.

• The air conditioner does not cool or warm

effectively.

• Remote control / display doesn’t work

This is the answer

• This is to protect the air conditioner. Wait until the air

conditioner begins to operate.

• This is the sound of refrigerant flowing inside the air

conditioner.

• Condensation occurs when the airflow from the air

conditioner cools the room.

• This may be a damp smell emitted by the wall,

carpet, furniture or clothing in the room.

• In COOL/DRY operation, moisture in the air

condenses into water on the cool surface of outdoor
unit piping that causes dripping.

• This is to remove the smell emitted by the

surroundings.

• This is to melt the frost which has accumulated on

the outdoor unit (defrosting operating). This will take
no longer than about 12 minutes. Water drips from
the outdoor unit. Wait until this operation ends.
(the power indicator will light up). (Frost will
accumulates on the outdoor unit when the outdoor
temperature is low and humidity is high.)

• This is to prevent undesired cooling effect during

heating operation.

Please check

• Has the circuit breaker been tripped?
• Has the power plug been removed from the wall

outlet?

• Is the timer being used correctly?

• Is the installation work slanted?

• Has the temperature been set incorrectly?
• Are the filters dirty?
• Are the intake or outlet vents of the outdoor unit

obstructed?

• Are all windows and doors closed?

• Batteries empty?
• Batteries correctly inserted (+) and (–)?

38

CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5

This manual is related to the following products: