Power connections, Console cooling, Entury – Peavey Century Series User Manual
Page 11: Eries

V
X
P
AGE
9
C
ENTURY
S
ERIES
Designed & manufactured in the USA by:
A division of Crest Audio Inc.
100 Eisenhower Dr.
Paramus, New Jersey 07652 USA
POWER OUT
POWER OUT
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION
AVIS : RISQUE DE CHOC ÉLECTRIQUE—NE PAS OUVRIR
WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT
EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE.
ATTENTION! POUR ÉVITER LE RISQUE D'INCENDIE OU DE CHOC
ÉLECTRIQUE, NE PLACEZ PAS CET APPAREIL SOUS LA PLUIE OU Á
L'HUMIDITÉ
6
7
2 1
4
5
3
Pin 1 +24V
Pin 2 +20V
Pin 3 Analog
Pin 4 Analog
Pin 5 Digital
Pin 6 +48V
Pin 7 -20V
CONSOLE
G R O U N D
CHASSIS
GROUND
MAXIMUM AC IN:
XCVA04: 415 WATTS
XCVA06: 825 WATTS
+ 48V @ 1
+ 24V @ 6
±
20V @ 6
Model XCVA06
Model XCVA04
±
20V @ 4
+ 24V @ 4
S/N
Designed & manufactured in the USA by:
A division of Crest Audio Inc.
100 Eisenhower Dr.
Paramus, New Jersey 07652 USA
POWER OUT
POWER OUT
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION
AVIS : RISQUE DE CHOC ÉLECTRIQUE—NE PAS OUVRIR
WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT
EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE.
ATTENTION! POUR ÉVITER LE RISQUE D'INCENDIE OU DE CHOC
ÉLECTRIQUE, NE PLACEZ PAS CET APPAREIL SOUS LA PLUIE OU Á
L'HUMIDITÉ
6
7
2 1
4
5
3
Pin 1 +24V
Pin 2 +20V
Pin 3 Analog
Pin 4 Analog
Pin 5 Digital
Pin 6 +48V
Pin 7 -20V
CONSOLE
G R O U N D
CHASSIS
GROUND
MAXIMUM AC IN:
XCVA04: 415 WATTS
XCVA06: 825 WATTS
+ 48V @ 1
+ 24V @ 6
±
20V @ 6
Model XCVA06
Model XCVA04
±
20V @ 4
+ 24V @ 4
S/N
To AC Mains
To AC Mains
Interface Cable
To Console
Power Connections
Before setting up the console, always check to make sure the
AC voltage marked on the power supply agrees with the local
supply. Always connect the console to the power supply before
switching on the power supply.
Multiple power supplies can be daisy-chained to provide fail-
safe protection in the event of a supply failure. When two or
more supplies are used, both power supplies run all the time. In
the event of supply failure, the remaining power supply(s) will
take over the entire load.
NOTE: Although both of the multi-pin connectors on the back
of the power supply are labeled “POWER OUT”, it is neces-
sary (and acceptable) to link two power supplies together as
shown in the diagram below.
ADDITIONAL NOTE: The multi-conductor cable used for
power supply-to-power supply connection is different than that
used for a conventional power supply-to-console connection,
and must be specified when the second power supply is
ordered.
Ground Link
Console Cooling
A dual-fan cooling configuration is included in all Vx consoles. Two fans (one at each end of the console) draw air in through the
sides of the chassis (under the sidebars). Air is distributed through the chassis via a “vortex pan”, then proceeds up through the
console modules, where the heated air exits the console chassis.
Once the console is powered up, cooling fans remain on. A rear panel switch permits the fans to be set at low, medium or high
speeds.
There are no filters to change or clean. As with any console, use in dusty/unclean environments should be avoided.