Pitco Frialator SOLSTICE SUPREME SSH55T User Manual
Page 2
![background image](/manuals/169921/2/background.png)
SOLSTICE SUPREME (SSH) SERIES SSH55(R), 55T(R), 60(R), 60W(R), 75(R) Gas Fryers
Pitco Frialator, Inc
P.O. Box 501, Concord, NH 03302-0501 509 Route 3A, Bow, NH 03304
603-225-6684
FAX: 603-225-8497
www.pitco.com
L10-266 Rev 4 04/12 Printed in the USA
We reserve the right to change specifications without notice and without incurring any obligation for equipment previously or subsequently sold
.
SOLSTICE SUPREME (SSH) SER
IES SSH55(R), 55T(R), 60(R),
60W(R), 75(R) Gas Fryers
IN/CM
CONTROL
52 11/32 [132.9]
6 1/4 [15.9]
19 5/8 [49.8]
38 11/32 [97.4]
9 [22.9]
NOM.
34 15/32 [87.5]
34 [86.4]
NOM.
12 13/16
[32.5]
NOM.
C
G
B
DIGITAL
SOLID STATE
THERMOSTAT
OPTIONAL
SSH55T (TR)
4 1/4 [10.8]
15 5/8 [39.7]
SSH55 (R)
48 11/32 [122.8]
B
C
A
SSH75 (R)
54 13/32
[138.2]
NOM.
A
1 13/32 [3.6]
10 1/2
[26.7]
NOM.
4 13/32 [11.2]
46 1/8
[117.1]
NOM.
G
P
INTEGRAL FLUE DEFLECTOR
OPTIONAL BASKET LIFT
11/16
[1.7]
52 11/32 [132.9]
SSH60 (R)
4 1/4 [10.8]
15 5/8 [39.7]
48 11/32 [122.8]
SSH60W (R)
19 5/8 [49.8]
6 1/4 [15.9]
P
3/4 INCH GAS CONNECTION
(CE 3/4 INCH BSP ADAPTOR
ADDS 1 1/2 [3.8] TO
CONNECTION)
6 FOOT (183 CM) POWER
CORD (NEMA 5-15 PLUG
115VAC UNITS ONLY)
P
G
50 - 60 Lbs (23 - 27 kg)
SSH60W, 60WR
18 x 14 in (45.7 x 35.6 cm)
3-1/4 - 5 in (8.3 -12.7 cm)
75 Lbs (34 kg)
SSH75, 75R
18 x 18 in (45.7 x 45.7 cm)
20 - 25 Lbs (9 -11 kg)
SSH55T, 55TR per side
7 x 14 in (35.6 x35.6cm)
3-1/4 - 5 in (8.3 -12.7 cm)
50 - 60 Lbs (23 - 27 kg)
SSH60, 60R
14 x 18 in (35.6 x 45.7 cm)
40 - 50 Lbs (18 - 23 kg)
SSH55, 55R
14 x 14 in (35.6 x 35.6 cm)
Cook Depth
Oil Capacity
Model
Frying Area
330 Lbs (150 kg)
Shipping Weight
SSH55T, SSH55TR
3-1/4 - 5 in (8.3 -12.7 cm)
3-1/4 - 5 in (8.3 -12.7 cm)
3-1/4 - 5 in (8.3 -12.7 cm)
308 Lbs (140 kg)
SSH55, SSH55R
208 Lbs (94.5 kg)
Model
6"
(15.25 cm)
Combustible material
Propane
Natural
CLEARANCES
Fryer Flue Area
Front min.
Floor min.
Non-Combustible material
* Check plumbing / gas codes for proper gas supply line sizing to sustain burner pressure when all gas appliances are full on.
Gas Type
326 Lbs (149 kg)
Store Supply Pressure *
275 Lbs (124.5 kg)
226 Lbs (102.5 kg)
275 Lbs (124.5 kg)
INSTALLATION INFORMATION
376 Lbs (171 kg)
376 Lbs (171 kg)
6" (15.2cm)
6" (15.2cm)
0"
Sides min.
Rear min.
SSH75, SSH75R
SSH60W,SSH60WR
INDIVIDUAL FRYER SPECIFICATIONS
FRYER SHIPPING INFORMATION (Approximate)
SSH60, SSH60R
Shipping Cube
Shipping Crate Size H x W x L
230 Lbs (104 kg)
Add for Each Bsk/Lifts
Amps
208 / 220-240V
115V
Rear min.
Do not block / restrict flue gases from flowing into hood
or install vent hood drains over the flue.
0"
Provide Pitco Solstice Supreme Model (SSH xxx) tube fired high efficiency / high production gas floor fryer with ENERGYSTAR
®**
performance. Fryer shall be
xx-xx lbs oil capacity, xxx Kbtu/hr, xx” by xx” fry area, stainless peened tank, stainless front, door, sides. Patented Blower Free atmospheric burner system
with up to 70% thermal efficiency, Patented self cleaning burners, down draft protection, matchless ignition, drain valve interlock, behind the door solid state t-
stat with melt and boil mode (or specify optional digital controller or computer controls), separate gas shut off, 3/4" npt rear gas connect, recessed cabinet
back, 1-1/4" Full port drain, 3/16" bottom hinge, 9” adjustable legs, manual reset high limit. If supplied with casters: Casters with 1" min. adjustment and front
toe locks. Provide options and accessories as follows:
SHORT FORM SPECIFICATIONS
0.4
0.7
1
30"
(76.2 cm)
Sides min.
Fryer
59 x 23 x 44 in (149.8 x 58.4 x 111.7 cm)
34.6 ft
3
. (1.0m
3
)
11 - 13" w.c.(27.4 mbars/ 2.7 kPa)
4" w.c. (10 mbars / 1 kPa)
10" w.c. (25mbars/2.4 kPa)
7 - 10" w.c.(17.4 mbars/ 1.7 kPa)
GAS SYSTEM REQUIREMENTS
ELECTRIC SYSTEM REQUIREMENTS (50/60 hz)
Burner Manifold Pressure
# of Cord