LK1: 75 Ohm Transmit Shield-to-Ground Connection

This setting determines whether the shield of the 75 Ohm (coax)

transmit cable is connected to earth ground. This connection must be
made when operating in 75 Ohm (unbalanced) mode. Conversely, this
connection must not be made when operating in 120 Ohm (balanced)
mode.

LK1

Setting

Strap On

75 Ohm TX Shield-to-GND Connection Made

Strap Off

75 Ohm TX Shield-to-GND Connection Broken

LK2: 75 Ohm Receive Shield-to-Ground Connection

This setting determines whether the shield of the 75 Ohm (coax)

receive cable is connected to earth ground. This connection is optional
when operating in 75 Ohm (unbalanced) mode. This connection must
not be made when operating in 120 Ohm (balanced) mode.

LK2

Setting

Strap On

75 Ohm RX Shield-to-GND Connection Made

Strap Off

75 Ohm RX Shield-to-GND Connection Broken

LK3: DIP Switch S1-1 Enable

This strap is reserved for future use and must remain Off.

LK3

Setting

Strap On

Not a Valid Setting

Strap Off

Normal Setting

LK4: 120 Ohm Shield-to-Ground Connection

This setting determines whether the shield of the 120 Ohm

(modular) cable is connected to earth ground. This connection is
optional when operating in 120 Ohm (balanced) mode. This connection
must not be made when operating in 75 Ohm (unbalanced) mode.

LK4

Setting

Strap On

75 Ohm RX Shield-to-GND Connection Made

Strap Off

75 Ohm RX Shield-to-GND Connection Broken

The table below shows the factory default jumper settings.

Following the table are descriptions for each jumper.

NOTE: one combination of jumper settings is required for 75 ohm
operation, and another combination is required for 120 ohm
operation. The Model 2703 is factory configured for 75 ohm
operation.)

7

8

JUMPER SUMMARY TABLE

Jumper

Function

75 ohm 120 ohm Factory Default

LK1

75 Ohm TX Shield to GND

On

Off

On (connect)

LK2

75 Ohm RX Shield to GND

Opt.*

Off

Off (disconnect)

LK3

Reserved

Off

LK4

120 Ohm Shield to GND

Off

Opt.

Off (disconnect)

LK5

Configuration Auto-Sense

On

Opt.

On (enabled)

LK6

75 Ohm Input Impedance

On

Off

LK7

75 Ohm Input Impedance

On

Off

}

On (75 Ohm)

*Opt. = optional setting, all others are required for proper operation

Figure 5. Jumper locations on Model 2703 PC board.

LK6
LK7
LK5
LK3

LK2

LK4
LK1