Read Stored Number

Selecting item 2 in the Dial Menu lets you view the phone number

currently stored in the Model 2500RC Series non-volatile memory.

Dial New Number

Selecting item 3 in the Dial Menu lets you dial a number other than

the one stored in non-volatile memory. When you select this menu
item, the Model 2500RC Series responds with this prompt:

Enter up to 12 digits (without hyphens or other alphabetic characters),
followed by [RETURN]. For example: “13015551212.”

After dialing the number, the Model 2500RC Series will display the
message, “Dialing” and then display each number as it is dialed. The
Model 2500RC Series will then prompt the user to wait while the
connection is made. One of the following messages will then be
displayed to indicate the success or failure or the connection:

CONNECT: The called unit has answered.

NO WINK: The central office did not send a wink signal
within 5 seconds of line seizure.

SHORT WINK: A wink signal less than 120 milliseconds
was received.

LONG WINK: A wink signal greater than 320 milliseconds
was received.

NO CARRIER: The called unit did not answer within 30
seconds.

DTR OFF: DTR must be on to dial.

OFF HOOK: The Model 2500RC Series is already off-hook
and in data mode.

NOTE: The control port will not respond to additional commands
until one of the above response messages is issued.

Hang Up

Selecting item 4 in the Dial Menu terminates the call.

APPENDIX A

SPECIFICATIONS

DDS Type:

Dedicated

Transmission Format:

Asynchronous, synchronous

Interface:

RS-232 and V.35

Standards:

AT&T 62310 compliant

DDS Line Rates:

2.4, 4.8, 9.6, 19.2, 56 and 64 Kbps

DTE Rates:

2.4, 4.8, 9.6, 19.2, 38.4, 56, and 64
Kbps; 57.6 Kbps, async, 2 stop bits

Control Port:

Configuration and diagnostics

Transmission Line:

4-wire

Applications:

DDS point-to-point or multipoint;
campus-area point-to-point

Indicators:

LED indicators for TD, RD, CTS, CD,
DTR, No Signal, Out-of-Service, Error
and Test Mode

Diagnostics:

V.54 compliant local and remote
loopback tests; V.52 compliant
511/511E BER test, TELCO CSU and
DSU loops

Connectors:

DB-25 and M/34

Power Supply:

115V or 230V AC

Dimensions:

7.3” x 6.6” x 1.6”

37

38

Data
Rate

64 Kbps

7.1

4.9

3.4

56 Kbps

7.6

5.2

3.6

19.2 Kbps

8.7

6.2

4.5

9600 bps

10.4

7.7

5.8

4800 bps

13.7

10.6

9.7

2400 bps

15.1

14.2

9.1

Model 2500RC Series Distance Table (miles)

Wire Gauge

22

24

26