Combination table, Cooling heating heating 6.2 heat pump, Cooling – LG LM50 2004-E1 User Manual
Page 24
2004 Product Data 23
6. Combination Table
Cooling
Heating
Heating
6.2 Heat Pump
6.2.1 A2UH146FA0
Combination(k Btu)
Capacity (Btu/h)
Cooling
Unit-A
Unit-B
Unit-C
Unit-D
Total
Input
(W)
Current
(A)
EER
(Btu/h.W)
A
B
C
D
Total
Operation
1 UNIT
7
-
-
-
7
9400
-
-
-
9400
1350
6.1
7.0
2 UNIT
7
7
-
-
14
7200
7200
-
-
14400
1450
6.6
9.9
Combination(k Btu)
Capacity (Btu/h)
Cooling
Unit-A
Unit-B
Unit-C
Unit-D
Total
Input
(W)
Current
(A)
EER
(Btu/h.W)
A
B
C
D
Total
Operation
7 -
-
-
7 7000 -
-
-
7000 780 3.5 9.0
1 UNIT
9
-
-
-
9
9500
-
-
-
9500
1100
5.0
8.6
12 -
-
-
12 11000 -
-
-
11000
1100 5.0 10.0
7 7 -
-
14 7000
7000 -
-
14000
1900 8.5 7.4
2 UNIT
7 9 -
-
16 7000
9000 -
-
16000
1900 8.5 8.4
9 9 -
-
18 9000
9000 -
-
18000
1900 8.5 9.5
7 12 -
-
19 7000
11000 -
-
18000 1900 8.5 9.5
Combination(k Btu)
Capacity (Btu/h)
Heating
Unit-A
Unit-B
Unit-C
Unit-D
Total
Input
(W)
Current
(A)
EER
(Btu/h.W)
A
B
C
D
Total
Operation
7 -
-
-
7 9000 -
-
-
9000
1300 6.0 6.9
1 UNIT
9
-
-
-
9
10500
-
-
-
10500
1250
5.6
8.4
12 -
-
-
12 12100 -
-
-
12100
1200 5.5 10.1
7 7 -
-
14 7700
7700 -
-
15400
1900 8.5 8.1
2 UNIT
7 9 -
-
16 7700
9900 -
-
17600
1900 8.5 9.3
9 9 -
-
18 9900
9900 -
-
19800
1900 8.5 10.4
7 12 -
-
19 7700
12100 -
-
19800 1900 8.5 10.4
Combination(k Btu)
Capacity (Btu/h)
Heating
Unit-A
Unit-B
Unit-C
Unit-D
Total
Input
(W)
Current
(A)
EER
(Btu/h.W)
A
B
C
D
Total
Operation
1 UNIT
7
-
-
-
7
10000
-
-
-
10000
1500
7.0
6.7
2 UNIT
7
7
-
-
14
7300
7300
-
-
14600
1300
6.0
11.2
Cooling