Installation, Technical specifications – idealarc® dc-600 vrd – Lincoln Electric IDEALARC IM10018-A User Manual
Page 9
60% Duty Cycle
122/61/49
68
A-1
INSTALLATION
IDEALARC® DC-600 VRD
A-1
TECHNICAL SPECIFICATIONS – IDEALARC® DC-600 VRD
Volts at Rated Amperes
44
44
44
Auxiliary Power
See the OPERATION section
for Auxiliary Power
information by model
Amps
600
680
750
Maximum Open Circuit Voltage
5V for 60 HZ models
5V for 50/60 HZ models
Duty Cycle
100% Duty Cycle
60% Duty Cycle
50% Duty Cycle
Output Range
70A/13V-780A/44V (CV)
90A/24V-780A/44V (CC)
INPUT - THREE PHASE ONLY
OUTPUT
1Also called “inverse time” or “thermal/magnetic” circuit breakers; circuit breakers which have a delay in tripping action that decreases as the magnitude of the current increases.
RECOMMENDED INPUT WIRE AND FUSE SIzES
Standard
Voltage
230/460/575/60
415/50/60
CODES
11613, 11707
11598, 11725
100% Duty Cycle
108/54/43
62
50% Duty Cycle
134/67/54
73
Input Current at Rated Output
RATED OUTPUT
INPUT
VOLTAGE /
FREQUENCY
230
460
575
415
TYPE 75°C
(SUPER LAG)
OR bREAKER
SIzE (AMPS)
1
175 Amp
90 Amp
70 Amp
100 Amp
TYPE 75°C
GROUND WIRE
IN CONDUIT
AWG(IEC-MM
2
) SIzES
6 (14)
8 (8.4)
8 (8.4)
8 (8.4)
TYPE 75°C
COPPER WIRE
IN CONDUIT
AWG(IEC-MM
2
) SIzES
30°C (86°F) Ambient
2 (34)
6 (14)
8 (8.4)
6 (14)
INPUT AMPERE
RATING ON
NAMEPLATE
108
54
43
61
HERTz
60
60
60
50/60
PHYSICAL DIMENSIONS
HEIGHT
30.75 in
781 mm
WIDTH
22.25 in
567 mm
DEPTH
39.0 in
988 mm
WEIGHT
525 lbs.
238 kg.