E-3

TROUbLESHOOTING

E-3

IDEALARC® DC-600 VRD

If all recommended possible areas
of possible cause have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service Facility.

PRObLEMS
(SYMPTOMS)

Major Physical or Electrical
Damage is Evident

The Machine is dead- The Input
contactor does not operate.

POSSIbLE
CAUSE

Contact the Lincoln Electric Service
Dept. (216) 383-2531 or 1-800-
833-9353 (WELD)

1. Check for blown or missing

fuses in input lines.

2. Check the three- phase input

line voltage at the machine.
The input voltage must match
the rating plate and reconnect
panel.

3. Power ON/OFF switch may be

defective.

4. Rectifier bridge may be defec-

tive.

5. VRD P.C. board may be defec-

tive.

RECOMMENDED
COURSE OF ACTION

OUTPUT PRObLEMS

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

Observe all Safety Guidelines detailed throughout this manual