beautypg.com

Condenser (outdoor) service replacement procedure – LG LP121CEM-Y8 User Manual

Page 47

background image

In this Model Aluminum Condenser is applied.
In case you need to replace the condenser follow the below mentioned steps:

1. Cover the brazing point (Section A) between copper pipe and aluminum pipe with wet towel.
2. Remove the copper pipe and copper connector of aluminum condenser(Section B) by brazing and replace the

condenser with a new one.

3. Make sure that the direction of brazing flame is away from the aluminum condenser.

(Follow the above procedure for assembling or disassembling the aluminum condenser)

- 47 -

Copyright ©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes

LGE Internal Use Only

CONDENSER (OUTDOOR) SERVICE REPLACEMENT PROCEDURE:

Copper pipe

Brazing point in
assembling or
disassembling

Cover the brazing point
with wet towel

Enlarged picture

Aluminum pipe

Section "B"

Section "B"

Section "B"

Section "A"

Section "A"

Section "A"