1. Specification

Cooling Capacity

kW

Btu/h.

Heating Capacity ( for Heat Pump models)

kW

Btu/h.

Electric Heater capacity

kW

Btu/h.

Power Input

Cooling/Heating

W

Running Current

Cooling/Heating

A

Starting current

Cooling/Heating

A

Electric Heater Current

A

EER

W/W

Btu/h.W

COP

W/W

Power Supply

Ø / V / Hz

Power Factor

%

Air Flow Rate

Indoor,Max

m

3

/min(CFM)

Outdoor,Max

m

3

/min(CFM)

Moisture Removal

l

/h

Sound Level

Indoor,H/M/L

dB(A)±3

(SoundPressure,1m)

Outdoor,Max

dB(A)±3

Refrigerant & Charge

g(oz)

Compressor

Type
Model
Motor Type
Oil Type
Oil Charge

cc

O.L.P Name

Fan

Type(In/Out)
Motor Type(In/Out)
Motor Output(In/Out)

W

Power Supply Cable (Power Cord)

No.*mm

2

Dimensions ( W * H * D)

mm

inch

Net Weight

kg(lbs)

Tool Code(Chassis)
Features

Temperature Control
Energy Saver Mode
Prefilter(washable/anti-fungus)
Plasma Filter
Steps, Fan/Cool/Heat
Airflow Direction Control(up&down)
Airflow Direction Control(left&right)
Remote Controller Type
Setting Temperature Range

Cooling
Heating

Auto Operation (Micom Control)
Panel Touch Type
Timer
Air Discharge
Air-Ventilation
Defrost Control
Hot Start
Look
Cabinet Type(Chassis Type)
Special Function

Model

LP121CEM-Y8

3.28

3.37

11300

11500

-

-

-

-

3.1

3.5

10500

11900

1045

1065

5.0 4.6

-

-

14.9

15.2

3.16 3.16
10.8

10.8

-

-

1 / 208 / 60

1 / 230 / 60

97.7

98.0

11(390)

-

1.5

51/-/47

63

R22, 585(20.6)

Rotary(Non Tropical)

QK145KBA

PSC

SUNISO 4GSI or NM56M

280

MRA 12054 - 12026

Cross Flow Fan / Axial Fan

4 Poles
18.4/60

3 * 2.1

1066*406*505

42*16*19-7/8

49.0(108.0)

YA

Thermistor

O
O

-

2/2/2

Manual

-

Wall Thermostat

54˚F ~ 86˚F(12.2˚C ~ 30˚C)

-
-

Mechanical controls

-

Rear

O

-
-

L - Look

Slide In-Out

Electric Heater

Note:
O : Applied, - : No relation
* For circuit breaker rating, please confirm to local standards wherever necessary.
❈ Some of functions are slightly different depending upon models.
❈ The specification may be subject to change without prior notice for purpose of improvement.