beautypg.com

Maintenance, Maintenance schedule – Lochinvar SQUIRE SIT119 User Manual

Page 18

background image

18

Installation & Operation Manual

7

Maintenance

* Make sure that the rest of the boiler and domestic

water piping is free of leaks.

* If there is an oil lubricated circulator in the system,

make sure it is lubricated as called for by the

circulator

manufacturer.

*

Make sure that the boiler is maintained in accordance

with the boiler manufacturer’s instructions.

* If a water treatment system is required to keep the

water chemistry within the parameters shown in

Table 2A (see Section 2 - Pre-Installation), make sure

that this system is properly maintained.

The Lochinvar SIT series indirect water heater is an extremely
simple device and as such requires very little maintenance.
There are, however, several items which should be checked
out on an annual or as needed basis to ensure a reliable supply
of hot water:

Maintenance Schedule

Annual service by a qualified service technician
should include the following:

 Any procedure required by local codes.

 Verify system pressure. Air venting procedure may

require adding water to bring boiler system up to

pressure, typically 12 psig.

 Manually operate T&P relief valve at least once a year.

This will release some hot water.

ƽ WARNING

Before operating a T&P relief valve, make
sure no one is in front of or around the
T&P relief valve discharge piping. Hot
discharge water can cause severe personal
injury or substantial property damage.

 Move operating lever to open position for a few

seconds and then move it back, allowing it to snap

closed. After the T&P relief valve is operated, if it

continues to release water, close the cold water inlet to

the water heater immediately. Follow the draining

instructions, and replace the T&P relief valve. If the

T&P relief valve weeps periodically, it may be due to

thermal expansion. Do not plug the T&P relief valve or

discharge

piping.

Homeowner monthly maintenance to include:

 Visually check valves, pipes, and fittings for leaks. Call a

qualified service technician to repair leaks.

To Fill the Water Heater

1. Close the water heater drain valve by turning the knob
clockwise.

2. Open the cold water supply shutoff valve.

3. Open several hot water faucets to allow air to escape from
the

system.

4. When a steady stream of water flows from the faucets, the

water heater is filled. Close the faucets and check for water

leaks at the water heater drain valve, combination

temperature and pressure relief valve and the hot and cold

water

connections.

ƽ DANGER

Plugging the T&P relief valve or discharge
piping can cause excessive pressure in the
water heater, resulting in severe personal
injury, death, or substantial property
damage.

ƽ WARNING

Water from opened drain valves, unions and
other connections may be extremely hot.

To avoid severe personal injury, death, or
substantial property damage:

-

Tighten all drain hose connections.

- Direct hot water away from all
persons.

To Drain the Water Heater

Should it become necessary to completely drain the water
heater, be sure to follow the steps below:

1. Disconnect the power supply to the heat source. Consult

the plumbing professional or electric company in your area

for

service.

2. Close the cold water supply shutoff valve.

3. Open the drain valve on the water heater.

4. Open a hot water faucet to allow air to enter the system.

• If boiler water does not contain sufficient

antifreeze, the boiler water and the domestic water

must

be

drained.

If antifreeze is used in the boiler water, check concentration.
Boiler water (including additives) must be practically non-toxic,
having a toxicity rating or class of 1, as listed in the “Clinical
Toxicology of Commercial Products”. A maximum 50/50
mixture of inhibited propylene glycol is recommended. Follow
the antifreeze manufacturer’s instructions.

ƽ WARNING

Do not use automotive, ethylene glycol or
petroleum-based antifreeze. Do not use
any undiluted antifreeze. This can cause
severe personal injury, death, or substantial
property damage.

Drain the water heater if it will be shut off and exposed to
freezing temperatures. Freezing water will expand and damage
the water heater.

• If boiler water contains sufficient antifreeze, then

only the domestic water needs to be drained.

 Follow instructions on circulator to oil, if required.
 Check mixing valve, valves, pipes, and fittings for leaks.
 Check function of the field-installed controls and valves.

See component manufacturer’s instructions.

 Review homeowner’s maintenance responsibilities and

their frequencies, including any not listed in the

following

section.