Installation & Operation Manual

4

Domestic Side (Tank) Piping

Temperature & Pressure (T&P) Relief Valve

For protection against excessive temperatures
and pressure, install temperature and
pressure protective equipment required by
local codes, but not less than a combination
temperature and pressure relief valve
certified by a nationally recognized
testing laboratory that maintains periodic
inspection of production of listed equipment
or materials as meeting the requirements for
Relief Valves and Automatic Gas Shutoff
Devices for Hot Water Supply Systems,
ANSI Z21.22 and the Standard CAN1-4.4,
Temperature, Pressure, Temperature and
Pressure Relief Valves and Vacuum Relief
Valves. The combination temperature and
pressure relief valve shall be marked with
a maximum set pressure not to exceed the
maximum working pressure of the water
heater. The combination temperature and
pressure relief valve shall also have an hourly
rated temperature steam BTU discharge
capacity not less than shown in Table 4A.

Install the combination temperature and
pressure relief valve into the opening
provided and marked for this purpose on
the water heater.

ƽ WARNING

Anti-scald Valves (Mixing Valves)

Anti-scald valves used with water heaters are also called
tempering valves or mixing valves. An anti-scald valve
mixes cold water in with the outgoing hot water to assure
that hot water reaching a building fixture is at a temperature
low enough to be safe. ASSE1017 and ASSE1070 certified
valves are recommended.

Usually, the maximum temperature of the outlet water will
stay near the setting of the tank control. In some cases,
however, hot water usage patterns can cause the outlet
water temperature to rise significantly above the control
setting.

The temperature of water going to the fixtures may be
more carefully controlled through the use of a thermostatic
mixing valve. This device blends a controlled amount of
cold water with the hot water leaving the tank so that water
at a more constant temperature exits the mixing valve.

Anti-scald mixing valve piping is illustrated in FIG.’s 3-1
thru 3-4.

Install Drain Valve

Drain valve and fittings are supplied by others.

Standard Installation

Install a tee connection at the domestic cold water

inlet

(FIG.

4-1).

DRAIN

VALVE

Figure 4-1 Drain Valve Installed

ƽ WARNING

An anti-scald mixing valve does not
eliminate the risk of scalding.

* Set the tank thermostat as low as
practical.

* Feel water before bathing or
showering.

*

If anti-scald or anti-chill protection

is required, use devices specifically

designed for such service. Install

these devices in accordance with

their manufacturer’s instructions.