beautypg.com

Installation, Warning caution – Lincoln Electric VINTAGE 400 (CE) IM889-A User Manual

Page 18

background image

A-8

INSTALLATION

VANTAGE

®

400 (CE)

A-8

Connection of the LN-25 to the VANTAGE 400 (CE)

Shut off welder before making any electrical con-

nections.

------------------------------------------------------------------------

The LN-25 with or without an internal contactor may
be used with the VANTAGE 400 (CE). See the
appropriate connection diagram in Section F.

NOTE: The LN-25 (K431) Remote Control Module

and (K432) Remote Cable are not recommended for

use with the VANTAGE 400 (CE).

1. Shut the welder off.

2. For electrode Positive, connect the electrode

cable from the LN-25 to the "+" terminal of the

welder and work cable to the "-" terminal of the

welder. For electrode Negative, connect the elec-

trode cable from the LN-25 to the "-" terminal of

the welder and work cable to the "+" terminal of

the welder.

3. Attach the single lead from the front of the LN-25

to work using the spring clip at the end of the lead.

This is a control lead to supply current to the wire

feeder motor; it does not carry welding current.

4. Set the MODE switch to the "CV-WIRE " position.

5. Set the "WELD TERMINALS" switch to "WELD

TERMINALS ON"

6. Set the "ARC CONTROL" knob to "0" initially and

adjust to suit.

7. Set the "IDLE" switch to the "AUTO" position.

W h e n n o t w e l di n g , t h e VA N T A G E 4 0 0 ( C E )

engine will be at the low idle speed. If you are

using an LN-25 with an internal contactor, the

electrode is not energized until the gun trigger is

closed.

8. When the gun trigger is closed, the current sens-

ing circuit will cause the VANTAGE 400 (CE)

engine to go to the high idle speed, the wire will

begin to feed and the welding process started.

When welding is stopped, the engine will revert to

low idle speed after approximately 12 seconds

unless welding is resumed.

If you are using an LN-25 without an internal con-

tactor, the electrode will be energized when the

VANTAGE 400 (CE) is started.

------------------------------------------------------------------------

WARNING

CAUTION