beautypg.com

Flow check (duct condition test) – LG DLEX3001W User Manual

Page 24

background image

Your dryer features FlowSense

TM

, an innovative

sensing system that automatically detects blockages

and restrictions in dryer ductwork. Keeping ductwork

clean of lint buildup and free of restrictions allows

clothes to dry faster and reduces energy use.
NOTE: When the dryer is first installed, this test

should be performed to alert you to any existing

problems with the exhaust duct in your home.

However, since the test performed during normal

operation provides more accurate information on

the condition of the exhaust duct than does the

installation test, the number of bars displayed during

the two tests may not be the same.

To activate the flow check (Duct condition test) :

NOTE: Dryer heating test must be performed before

proceeding. Then perform the duct condition test

below:

Press and hold the DAMP DRY BEEP and

TEMP. CONTROL buttons at the same time.

While holding these buttons, press POWER

ON/OFF.

The display will show the FLOW CHECK start

screen.

FLOW CHECk (DUCT CONDITION TEST)

Correct Venting

Restricted or Blocked Airflow

Avoid long runs or runs with multiple elbows

or bends.

Check for blockages and lint buildup.

Make sure the ductwork is not crushed

or restricted.

1

2

3

If no bars are shown in

the display, the ductwork

is free from blockages

or restrictions.

If all bars are lit, the

dryer ductwork has a

blockage that needs to

be removed immediately.

IMPORTANT: Do NOT interrupt the test cycle!

THE DUCTWORK IS FREE

FROM BLOCKAGES OR

RESTRICTIONS.

COMPLETED FLOW CHECK

THE DUCTWORK HAS

A BLOCKAGE THAT NEEDS

TO BE REMOVED

IMMEDIATELY.

NEED FLOW CHECK

Press START/PAUSE. The dryer

will run for approximately 2

minutes to test

for blockages

or restrictions

to air flow in the

ductwork.

FLOW CHECK

0:02

EST. TIME

REMAINING

HIGH