Flow check (duct condition test) – LG DLEX3001W User Manual
Page 24
Your dryer features FlowSense
TM
, an innovative
sensing system that automatically detects blockages
and restrictions in dryer ductwork. Keeping ductwork
clean of lint buildup and free of restrictions allows
clothes to dry faster and reduces energy use.
NOTE: When the dryer is first installed, this test
should be performed to alert you to any existing
problems with the exhaust duct in your home.
However, since the test performed during normal
operation provides more accurate information on
the condition of the exhaust duct than does the
installation test, the number of bars displayed during
the two tests may not be the same.
To activate the flow check (Duct condition test) :
NOTE: Dryer heating test must be performed before
proceeding. Then perform the duct condition test
below:
Press and hold the DAMP DRY BEEP and
TEMP. CONTROL buttons at the same time.
While holding these buttons, press POWER
ON/OFF.
The display will show the FLOW CHECK start
screen.
FLOW CHECk (DUCT CONDITION TEST)
Correct Venting
Restricted or Blocked Airflow
Avoid long runs or runs with multiple elbows
or bends.
Check for blockages and lint buildup.
Make sure the ductwork is not crushed
or restricted.
1
2
3
If no bars are shown in
the display, the ductwork
is free from blockages
or restrictions.
If all bars are lit, the
dryer ductwork has a
blockage that needs to
be removed immediately.
IMPORTANT: Do NOT interrupt the test cycle!
THE DUCTWORK IS FREE
FROM BLOCKAGES OR
RESTRICTIONS.
COMPLETED FLOW CHECK
THE DUCTWORK HAS
A BLOCKAGE THAT NEEDS
TO BE REMOVED
IMMEDIATELY.
NEED FLOW CHECK
Press START/PAUSE. The dryer
will run for approximately 2
minutes to test
for blockages
or restrictions
to air flow in the
ductwork.
FLOW CHECK
0:02
EST. TIME
REMAINING
HIGH