beautypg.com

Troubleshooting, Caution – Lincoln Electric MIG PULSER IM555 User Manual

Page 17

background image

D-2

TROUBLESHOOTING

D-2

MIG PULSER

Observe all Safety Guidelines detailed througout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local
Lincoln Authorized Field Service Facility
for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENTS(S)

RECOMMENDED

COURSE OF ACTION

The MIG PULSER does not give a
satisfactory Weld.

The voltmeter on the wire feeder (if
equipped) will not display.

1. Incorrect settings at the V300.

Make sure the V300 switches are
set in the proper positions. See
V300 SETTINGS in the
Operation section of this manual.

2. Output Cables are either too long

or of improper size. See

OUT-

PUT CABLES FOR PULSE
WELDING
in the Installation sec-
tion of this manual.

3. The control cable may be extend-

ed too long. Do not use more
than one optional 25 foot control
cable extension.

4. There may be high frequency

interference. Refer to the

HIGH

FREQUENCY INTERFERENCE
PROTECTION
section in the
Installation section of this manual
for proper installation guidelines.

1. This is normal. The wire feeder

voltmeter will not display since
there is no 21 lead in the feeder
connection.

Contact your Local Lincoln Authorized
Field Service Facility
for technical
troubleshooting assistance.