beautypg.com

Connect the cable to the indoor unit, Service manual 33 – LG A2UH243FA0(LMU240HE) User Manual

Page 33

background image

Service Manual 33

Connect the cable to the indoor unit

CAUTION: Provide a circuit breaker between power source and the unit as shown

below.

Air

Conditioner

Circuit Breaker
Use a circuit
breaker or time
delay fuse.

Main power source

Model

24k

1Ø, 230/208V

25A

Power source Fuse or breaker

Capacity

1. Connect the wires to the terminals on the control board

individually according to the outdoor unit connection.

• Ensure that the color of the wires of outdoor unit and the

terminal No. are the same as those of indoor unit respec-
tively.

2. Attach the Grille onto the cabinet.

• Grasp the lower left and right side of the Grille and

engage four tabs on the top inside edge of the chassis.

• Press the Grille toward the chassis until it will be back into

place.

Connecting cable

Connecting the Cable between Indoor Unit and Outdoor Unit