Service Manual 19

Installation

Preparing work for Installation (Artcool Type Only)

Open panel front

1. First, push the front panel backward and lift it up to remove the two screws.

2. The moment of lifting the both lower parts of panel front, you can hear sound this panel came out, In this time panel front is

separated

3. After pull down this panel a bit, and separate connecting wire with product.

Remove cover pipe and cover side

1. Remove two screws(for fixing cover pipe)
2. Pull up the cover side of desired connecting direction, then cover

side is separated.

3. In case of connecting direction is left or right, path through the

hole of cover side.

CAUTION: After removing the pipe hole, cut the

burr for safety.

When connecting pipe path through rear
wall, don’t remove the hole.

NOTICE

Drain hose junction

1. Remove the rubber stopple of desired direction of

drainage.

2. As the following picture, Insert drain hose in the

handle of drain pan, and join drain hose and con-
necting hose.

Panel Front

Connector

Pipe hole

rubber cap

Only one

desiring direction

Connecting

part

Adhesive

Drain