beautypg.com

Power, battery, & ground wiring, Rs-232 port – Linear AE-2000 User Manual

Page 11

background image

11

220231 B IMAGE 11

Power, Battery, & Ground Wiring

Power Wiring

NOTE: DO NOT APPLY POWER UNTIL THE INSTALLATION IS

COMPLETE. TURN MASTER POWER SWITCH OFF BEFORE
WIRING.

1. Route two wires between the AE-2000 and the power transformer.

• For power wire runs up to 75 feet, use 18 AWG, THHN 600-volt

insulated wire.

• For power wire runs up to 150 feet, use 16 AWG, THHN 600-volt

insulated wire.

2. Connect the wires to the transformer. Connect the other end of the

wires to the AE-2000 AC1 & AC2 terminals.

Backup Battery / Uninterruptable Power Supply

Use of battery backup is optional. It will allow the AE-2000 to operate for
short periods of time without AC power. The door or gate access device
must use some type of battery backup of its own for the entire system to
be functional.
A backup battery will not fi t into the AE-2000 case. Protect the backup
battery inside a rain-tight NEMA enclosure suitable for the installation.

NOTE: A backup battery is not required to maintain the AE-2000

clock/calendar and programming memory during power outages.

1. Route two wires between the AE-2000 and the backup battery.
2. Connect the Battery positive to the AE-2000 DC+ terminal and the

negative to the DC- terminal.

NOTE: The AE-2000 does not supply battery charging current.

An external battery charger will be required to maintain the battery.

Earth Ground

For the best ground, use size 12 gauge solid wire or larger to connect to
an 8-foot copper ground rod. Locate the ground rod next to the Power and
Telephone company rods and bond the rods together with a new clamp.
Do not disturb the clamps installed by the Power or Telephone Company.
Alternately, connect to a metallic cold water pipe for the earth ground.

1. Connect the wire from the earth ground to the AE-2000’s EARTH

GROUND STUD.

RS-232 Port

A modular connector is provided for the bi-directional 38.4K baud RS-232
port. The AE-2000’s RS-232 port connects to a personal computer’s COM
port. System programming can be performed locally with a computer
connected to the RS-232 port using the AccessBase 2000 software.

16 VAC

50 VA

TRANSFORMER

EARTH

GROUND

STAKE

12 VOLT

BATTERY

POWER

TERMINALS

EARTH

GROUND

STUD

NOTE: THE OPTIONAL

BACKUP BATTERY

WILL REQUIRE AN

EXTERNAL CHARGER

DC

DC

AC

2

AC1

AE-2000

RS-232 PORT

COMPUTER'S

COM PORT

LINEAR MODEL A2C

SERIAL COMPUTER CABLE

SET COMPUTER COM PORT

BAUD RATE TO 38,400 BPS

NOTE: USE A DB-25 TO DB-9 CABLE ADAPTER IF REQUIRED